Mechanical Circulatory Support in Children: Strategies, Challenges and Future Directions

Autor(es): Abreu, S ; Brandão, C ; Trigo, C ; Rodrigues, R ; Pinto, F ; Fragata, J

Data: 2022

Identificador Persistente: http://hdl.handle.net/10400.17/4760

Origem: Repositório do Centro Hospitalar de Lisboa Central, EPE

Assunto(s): HSM CAR PED; HSM CCT; Bridge to Transplant; Bridge-to-Bridge; Heart Transplant; ECMO; Mechanical Circulatory Support; Paracorporeal Pulsatile Ventricular Assist Devices; Short Term Ventricular Assist Devices; Pediatric


Descrição

Introduction: The use of mechanical circulatory support (MCS) in the pediatric population has evolved significantly in the past 20 years, but its management still poses several challenges. We aim to describe patient characteristics, outcomes, and morbidity associated with different modalities of MCS, in a tertiary center. Methods: Retrospective analysis of data from all the children who underwent MCS between 2002 and 2018 at a pediatric cardiology unit. Results: Between 2002 and 2018, 22 devices were implanted in 20 patients. Patients were divided into three groups: Group A (n=11) extracorporeal membrane oxygenator (ECMO); Group B (n=8) pulsatile paracorporeal ventricular assist device (VAD) and group C (n=3) paracorporeal continuous flow VAD. The median age was similar in groups A and B (18 and 23 months, respectively), and higher in group C (13 years). ECMO patients were cannulated mainly as a bridge to recovery (post cardiotomy- 8) while group B and C patients were bridged to transplantation. The most frequent complications were bleeding (group A - 36%, group C - 66.6%) and thromboembolic events (group B - 50%, group C - 33.3%). As for outcomes, in group A the majority of patients (54.5%) were weaned and 27.3% died. Half of group B and all of group C patients underwent transplantation. Conclusion: Bleeding and thromboembolic events were the main complications observed. Group B showed the highest mortality, probably related to the low weight of the patients. Overall, outcomes and complications are related to the type of device and patient status and characteristics.

Tipo de Documento Artigo científico
Idioma Inglês
Contribuidor(es) Repositório da Unidade Local de Saúde São José
facebook logo  linkedin logo  twitter logo 
mendeley logo

Documentos Relacionados

Não existem documentos relacionados.