6 documents found, page 1 of 1

Sort by Issue Date

Quadripolar Left Ventricle Only Single Lead Pacing in a Patient With a Tricuspi...

Grazina, A; Teixeira, B; Silva Cunha, P; Oliveira, M

In the presence of prosthetic tricuspid valve, the inaccessibility to the right ventricle makes permanent pacing challenging. The placement of a left ventricle (LV) single lead in the coronary sinus (CS) is a well-accepted alternative, with some limitations regarding sensing and threshold. We describe a clinical case of a patient who had a previous LV only lead in the CS due to the presence of a prosthetic tric...


Heterotopic Caval Valve-in-Valve Procedure for Prosthetic Migration: Two Case R...

Grazina, A; Ferreira, A; Ramos, R; Cacela, D

Background: Heterotopic bicaval stenting or caval valve implantation (CAVI) either with non-dedicated balloon-expandable Sapien™ valves (Edwards Lifesciences) or with dedicated TricValve™ (Products + Features) has emerged as a safe and effective percutaneous treatment for high-risk patients with severe tricuspid regurgitation (TR). One technical difficulty of CAVI is the lack of native calcified structures to a...


Validation of a Heart Failure Risk Score in a Cohort of Cardiac Resynchronizati...

Cardoso, I; Cunha, P; Laranjo, S; Grazina, A; Viegas, J; Portugal, G; Valente, B; Lousinha, A; Brás, P; Brás, M; Cruz Ferreira, R; Oliveira, M

The heart failure risk status (HFRS) is a validated dynamic tool for risk score prediction, based on the TriageHF™ algorithm (Medtronic, Minneapolis, MN, USA), for the occurrence of a heart failure (HF) event in the 30 days following a remote monitoring (RM) transmission. The aim of this study was to evaluate the accuracy of the HFRS in predicting an unplanned hospital admission due to HF decompensation in a re...


Initial Single-Center Experience of a Standardized Protocol for Invasive Assess...

Vaz Ferreira, V; Ramos, R; Castelo, A; Mendonça, T; Almeida-Morais, L; Pereira-da-Silva, T; Oliveira, E; Viegas, J; Garcia Brás, P; Grazina, A

Introduction: Coronary vasomotion disorders (CVDs), including microvascular angina (MVA) and vasospastic angina (VSA), account for significant morbidity among patients with non-obstructive coronary artery disease (NOCAD). However, protocols for CVD assessment in clinical practice are seldom standardized and may be difficult to implement. Purpose: To assess the safety and feasibility of a comprehensive coronary ...



Transcatheter Aortic Valve Implantation Outcomes in Patients with Low Flow Low ...

Castelo, A; Grazina, A; Mendonça, T; Rodrigues, I; Garcia Brás, P; Ferreira, V; Ramos, R; Fiarresga, A; Cacela, D; Cruz Ferreira, R

Background: Some studies suggest that patients with low flow low gradient (LF-LG) aortic stenosis (AS) may achieve worse results after undergoing transcatheter aortic valve implantation (TAVI). Purpose: To compare outcomes between LF-LG AS and high gradient (HG) AS patients submitted to TAVI. Methods: Inclusion of 480 consecutive patients who underwent TAVI between 2008 and 2020 at a single tertiary center. Pat...


6 Results

Queried text

Refine Results

Author





















Date



Document Type



Access rights


Resource


Subject