Author(s):
Fernandes, M.G.A. ; Fonseca, E.M.M. ; Natal, Renato ; Dias, Maria Isabel Ribeiro ; Lopes, Ana Catarina Oliveira ; Ribeiro, J.E.
Date: 2016
Persistent ID: http://hdl.handle.net/10198/13432
Origin: Biblioteca Digital da UPB
Subject(s): Ex-vivo bovine bone; Drilling; Temperatures; Thermocouples; Infrared camera
Description
he thermal bone necrosis induced during a drilling process is a frequent and potential phenomenon, which contributes to post-operative problems. The frictional heat generated from the contact between the drill bit and the hole wall is unavoidable. However, understanding advanced techniques for acquiring reliable thermal data on bone drilling is important to ensure the quality of the drilled hole.