Document details

Towards a consistent safety format of steel beam-columns: application of the new interaction formulae from ambient temperature to elevated temperatures

Author(s): Vila Real, Paulo M.M. ; Lopes, Nuno ; Silva, Luís Simões ; Piloto, P.A.G. ; Franssen, J.-Marc

Date: 2003

Persistent ID: http://hdl.handle.net/10198/2111

Origin: Biblioteca Digital da UPB

Subject(s): Beam-column; Buckling; Lateral-torsional-buckling; Fire; Eurocode 3; Numerical modelling


Description

Two new formulae for the design of beam-columns at room temperature have been proposed into Eurocode 3, prEN 1993-1-1 (2002), and are the result of great efforts made by two working groups that followed different approaches, a French-Belgian team and an Austrian-German one. Under fire conditions the prEN 1993-1-2 (structural fire design) presents formulae, for the design of beam-columns based on the prENV 1993-1-1 (1992). In order to study the possibility of having, in part 1-1 and part 1-2 of the Eurocode 3, the same approach, a numerical research was made using the finite element program SAFIR, developed at the University of Liege for the study of structures subjected to fire.

Document Type Journal article
Language English
Contributor(s) Biblioteca Digital da UPB
facebook logo  linkedin logo  twitter logo 
mendeley logo

Related documents