Comparação de resíduos de gases anestésicos em salas de operação com ou sem sistema de exaustão em hospital universitário brasileiro

Autor(es): Braz, Leandro Gobbo [UNESP] ; Braz, José Reinaldo Cerqueira [UNESP] ; Cavalcante, Guilherme Aparecido Silva [UNESP] ; Souza, Kátina Meneghetti [UNESP] ; Lucio, Lorena Mendes de Carvalho [UNESP] ; Braz, Mariana Gobbo [UNESP]

Data: 2018

Identificador Persistente: http://hdl.handle.net/11449/174280

Origem: Oasisbr

Assunto(s): Indoor air pollution; Inhaled anesthetics; Occupational exposure; Operating rooms; Indoor air pollution; Indoor air pollution; Inhaled anesthetics; Inhaled anesthetics; Occupational exposure; Occupational exposure; Operating rooms; Operating rooms


Descrição

Made available in DSpace on 2018-12-11T17:10:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2017-09-01

Background and objectives Occupational exposure to waste anesthetic gases in operating room (OR) without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhaled anesthetics isoflurane and sevoflurane in OR with and without central scavenging system. Method Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120 minutes after the start of surgery) in both OR types. Results All isoflurane and sevoflurane concentrations in unscavenged OR were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged OR, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. Conclusions The exposure to both anesthetics exceeded the international limit in unscavenged OR. In scavenged OR, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the OR scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.

Universidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP) Faculdade de Medicina Hospital das Clínicas

Universidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP) Faculdade de Medicina Hospital das Clínicas

Tipo de Documento Artigo científico
Idioma Inglês
facebook logo  linkedin logo  twitter logo 
mendeley logo

Documentos Relacionados