Document details

Validation of ACB in vitro and in vivo as a biomagnetic method for measuring stomach contraction

Author(s): Americo, Madileine Francely [UNESP] ; Marques, Rozemeire Garcia [UNESP] ; Zandona, E. A. [UNESP] ; Andreis, Uilian de [UNESP] ; Stelzer, Marcelo [UNESP] ; Cora, Luciana Aparecida ; Oliveira, Ricardo Brandt de ; Miranda, José Ricardo de Arruda [UNESP]

Date: 2014

Persistent ID: http://hdl.handle.net/11449/17687

Origin: Oasisbr

Subject(s): Digestive physiology; Food; Gastrointestinal motility; Investigative techniques; Rats; Transducers; Digestive physiology; Digestive physiology; Food; Food; Gastrointestinal motility; Gastrointestinal motility; Investigative techniques; Investigative techniques; Rats; Rats; Transducers; Transducers


Description

Made available in DSpace on 2013-08-12T17:56:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-01

Made available in DSpace on 2013-09-30T18:37:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-01

Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-20T13:49:36Z No. of bitstreams: 0

Made available in DSpace on 2014-05-20T13:49:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-01

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

UNESP Univ Estadual Paulista, Dept Fis & Biofis, Inst Biociencias, BR-18618000 São Paulo, Brazil

UFMT Univ Mato Grosso, Inst Ciencias Biol & Saude, Barra do Garcas, Mato Grosso, Brazil

Univ Estadual Paulista UNESP, Fac Med, Dept Cirurgia & Ortopedia, BR-18618000 São Paulo, Brazil

Univ São Paulo, Fac Med, Dept Clin Med, São Paulo, Brazil

UNCISAL Alagoas State Univ Hlth Sci, Maceio, Alagoas, Brazil

UNESP Univ Estadual Paulista, Dept Fis & Biofis, Inst Biociencias, BR-18618000 São Paulo, Brazil

Univ Estadual Paulista UNESP, Fac Med, Dept Cirurgia & Ortopedia, BR-18618000 São Paulo, Brazil

Document Type Journal article
Language English
facebook logo  linkedin logo  twitter logo 
mendeley logo

Related documents

No related documents