This paper introduces a methodology to model and control a single-phase inverter with LCL filter intended for low power PV distributed generation in microgrid scenario. The system should operate in grid connected and island modes with a smooth transition between them. The control strategy is to split the system into two: the internal voltage subsystem and the external injected current subsystem. These two subsystems are modeled in state-space considering disturbances and uncertain parameters. By using linear matrix inequalities (LMI) two state-feedback H
São Paulo State University - UNESP, Power Electronics Laboratory
Federal Technological University of Paraná - UTFPR, Electrical Engineering Department
São Paulo State University - UNESP, Power Electronics Laboratory