Detalhes do Documento

Development and application of a portable instrument for drugs analysis in pharmaceutical preparations

Autor(es): Ribeiro, Paulo Roberto da Silva ; Pezza, Helena Redigolo [UNESP] ; Pezz, Leonardo [UNESP] ; Lima, Liliane Spazzapam [UNESP] ; Tubino, Matthieu

Data: 2018

Identificador Persistente: http://hdl.handle.net/11449/177622

Origem: Oasisbr

Assunto(s): Drugs/ quantitative analysis; Drugs/dosage; Instrumentation/drugs dosage; Optical sensor/application/colorimetric analysis; Pharmaceutical formulations/quality control; Drugs/ quantitative analysis; Drugs/ quantitative analysis; Drugs/dosage; Drugs/dosage; Instrumentation/drugs dosage; Instrumentation/drugs dosage; Optical sensor/application/colorimetric analysis; Optical sensor/application/colorimetric analysis; Pharmaceutical formulations/quality control; Pharmaceutical formulations/quality control


Descrição

Made available in DSpace on 2018-12-11T17:26:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-01. Added 1 bitstream(s) on 2019-10-09T18:32:19Z : No. of bitstreams: 1 S1984-82502015000300699.pdf: 632401 bytes, checksum: 2263f32dbf11c4cb4074c8c2cad2a91b (MD5)

This article describes the application and performance of an inexpensive, simple and portable device for colorimetric quantitative determination of drugs in pharmaceutical preparations. The sensor is a light detector resistor (LDR) incorporated into a black PTFE cell and coupled to a low-cost multimeter (Ohmmeter). Quantitative studies were performed with captopril/p-chloranil/H2O2 and methyldopa/ ammonium molybdate systems. Calibration curves were obtained by plotting the electrical resistance of the LDR against the concentration of the colored species in the ranges 1.84 x 10-4 to 1.29 x 10-3 mol L-1 and 5.04 x 10-4 to 2.52 x 10-3 mol L-1 for captopril/p-chloranil/H2O2 and methyldopa/ammonium molybdate systems, respectively, exhibiting good coefficients of determination. Statistical analysis of the results obtained showed no significant difference between the proposed methodologies and the official reported methods, as evidenced by the t-test and variance ratio at a 95% confidence level. The results of this study demonstrate the applicability of the instrument for simple, accurate, precise, fast, in situ and low-cost colorimetric analysis of drugs in pharmaceutical products.

Centre for Social Science Health and Technology Federal University of Maranhão

Institute of Chemistry São Paulo State University UNESP

Department of Analytical Chemistry Institute of Chemistry State University of Campinas UNICAMP

Institute of Chemistry São Paulo State University UNESP

Tipo de Documento Artigo científico
Idioma Inglês
facebook logo  linkedin logo  twitter logo 
mendeley logo

Documentos Relacionados

Não existem documentos relacionados.