Detalhes do Documento

Microbiological analysis in the fixation and preservation of dog cadavers with ethyl alcohol and sodium chloride solution

Autor(es): Pereira, Natália [UNESP] ; Cardozo, Marita Vedovelli [UNESP] ; De Sá Rocha, Thiago André Salvitti [UNESP] ; Zero, Raphael Chiarelo [UNESP] ; De Ávila, Fernando Antônio [UNESP] ; De Oliveira, Fabrício Singaretti [UNESP]

Data: 2020

Identificador Persistente: http://hdl.handle.net/11449/199879

Origem: Oasisbr

Assunto(s): Anatomy; Animal; Bacterium; Microbiological counting; Surgery; Anatomy; Anatomy; Animal; Animal; Bacterium; Bacterium; Microbiological counting; Microbiological counting; Surgery; Surgery


Descrição

Made available in DSpace on 2020-12-12T01:51:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-01-01

There are several fixative or preservative solutions for use on cadavers, and formaldehyde is the most widely used. However, this chemical may present negative effects for professionals who manipulate it. Therefore, this study aimed to identify and quantify the main microorganisms related to the fixation and preservation of dog cadavers using an alternative and formaldehyde-free solution. After arterial injection (120 mL kg-1 95% 96° GL ethyl alcohol and 5% pure glycerin), cadavers were placed in 96° GL ethyl alcohol for 30 (group 1), 60 (group 2), 90 (group 3), and 120 days (group 4). After the fixation period, they remained under preservation in a 30% aqueous sodium chloride solution for 120 days. Bacterial quantification was performed by the pour plate method. The bacterial population was present in all groups during fixation, except for group 1, but never exceeded 9 × 101 CFU mL-1 in total aerobes and 7 × 101 CFU mL-1 in total anaerobes. The microbial population was present in all groups in at least two moments during preservation and never exceeded 7 × 101 CFU mL-1 in total aerobes and anaerobes. The presence of fungi was observed in 8 out of 34 analyses. Pseudomonas sp., Escherichia coli, and Bacillus sp. were identified in the analyzed samples. Microbiological counting was low, and no signs of contamination were observed in the vats at visual inspection.

Departamento de Patologia Veterinária Faculdade de Ciências Agrárias e Veterinárias Universidade Estadual Paulista UNESP

Pós-Graduando em Cirurgia Veterinária UNESP

Departamento de Patologia Veterinária UNESP

Departamento de Morfologia e Fisiologia Animal UNESP

Departamento de Patologia Veterinária Faculdade de Ciências Agrárias e Veterinárias Universidade Estadual Paulista UNESP

Pós-Graduando em Cirurgia Veterinária UNESP

Departamento de Patologia Veterinária UNESP

Departamento de Morfologia e Fisiologia Animal UNESP

Tipo de Documento Artigo científico
Idioma Inglês
facebook logo  linkedin logo  twitter logo 
mendeley logo

Documentos Relacionados