Autor(es):
Otenio, Marcelo Henrique ; Panchoni, Luciana Cadioli ; Cruz, Gabriela Correia Araújo da ; Ravanhani, Clézio ; Bidoia, Ederio Dino [UNESP]
Data: 2013
Identificador Persistente: http://hdl.handle.net/11449/20094
Origem: Oasisbr
Assunto(s): electrolytic treatment; water disinfection; water quality; electrolytic treatment; electrolytic treatment; water disinfection; water disinfection; water quality; water quality
Descrição
Submitted by Guilherme Lemeszenski (guilherme@nead.unesp.br) on 2013-08-22T18:48:42Z No. of bitstreams: 1 S0100-40422008000300008.pdf: 318531 bytes, checksum: 285301a9a14985b65702756a2d7515e3 (MD5)
Made available in DSpace on 2013-08-22T18:48:42Z (GMT). No. of bitstreams: 1 S0100-40422008000300008.pdf: 318531 bytes, checksum: 285301a9a14985b65702756a2d7515e3 (MD5) Previous issue date: 2008-01-01
Made available in DSpace on 2013-09-30T19:38:44Z (GMT). No. of bitstreams: 2 S0100-40422008000300008.pdf: 318531 bytes, checksum: 285301a9a14985b65702756a2d7515e3 (MD5) S0100-40422008000300008.pdf.txt: 29620 bytes, checksum: c39620a83f8500f8cf1cc6cf9a220aba (MD5) Previous issue date: 2008-01-01
Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-20T13:56:11Z No. of bitstreams: 2 S0100-40422008000300008.pdf: 318531 bytes, checksum: 285301a9a14985b65702756a2d7515e3 (MD5) S0100-40422008000300008.pdf.txt: 29620 bytes, checksum: c39620a83f8500f8cf1cc6cf9a220aba (MD5)
Made available in DSpace on 2014-05-20T13:56:11Z (GMT). No. of bitstreams: 2 S0100-40422008000300008.pdf: 318531 bytes, checksum: 285301a9a14985b65702756a2d7515e3 (MD5) S0100-40422008000300008.pdf.txt: 29620 bytes, checksum: c39620a83f8500f8cf1cc6cf9a220aba (MD5) Previous issue date: 2008-01-01
Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.
Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Gado de leite
Serviço Autônomo de Água e Esgoto Laboratório de Análises Físico-Químicas e Microbiológicas de Água e Esgoto
Universidade Estadual Paulista Instituto de Biociências Departamento de Bioquímica e Microbiologia
Universidade Estadual Paulista Instituto de Biociências Departamento de Bioquímica e Microbiologia