Document details

Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano

Author(s): Claro, Elis Marina Turini ; Otenio, Marcelo Henrique ; Bidoia, Ederio Dino [UNESP] ; Silva, Natália Maria Maciel Guerra ; Santos, Valdecir dos

Date: 2013

Persistent ID: http://hdl.handle.net/11449/20095

Origin: Oasisbr

Subject(s): electrolysis; treatment of effluent; disinfection; electrolysis; electrolysis; treatment of effluent; treatment of effluent; disinfection; disinfection


Description

Submitted by Guilherme Lemeszenski (guilherme@nead.unesp.br) on 2013-08-22T18:48:49Z No. of bitstreams: 1 S0100-40422010000300012.pdf: 542689 bytes, checksum: 84c50dd37285bda4faefc9866fb6f0f7 (MD5)

Made available in DSpace on 2013-08-22T18:48:49Z (GMT). No. of bitstreams: 1 S0100-40422010000300012.pdf: 542689 bytes, checksum: 84c50dd37285bda4faefc9866fb6f0f7 (MD5) Previous issue date: 2010-01-01

Made available in DSpace on 2013-09-30T19:38:53Z (GMT). No. of bitstreams: 2 S0100-40422010000300012.pdf: 542689 bytes, checksum: 84c50dd37285bda4faefc9866fb6f0f7 (MD5) S0100-40422010000300012.pdf.txt: 31172 bytes, checksum: e155e93aecb43994785d786dcfe88c4e (MD5) Previous issue date: 2010-01-01

Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-20T13:56:12Z No. of bitstreams: 2 S0100-40422010000300012.pdf: 542689 bytes, checksum: 84c50dd37285bda4faefc9866fb6f0f7 (MD5) S0100-40422010000300012.pdf.txt: 31172 bytes, checksum: e155e93aecb43994785d786dcfe88c4e (MD5)

Made available in DSpace on 2014-05-20T13:56:12Z (GMT). No. of bitstreams: 2 S0100-40422010000300012.pdf: 542689 bytes, checksum: 84c50dd37285bda4faefc9866fb6f0f7 (MD5) S0100-40422010000300012.pdf.txt: 31172 bytes, checksum: e155e93aecb43994785d786dcfe88c4e (MD5) Previous issue date: 2010-01-01

Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of salt. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of salt, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.

Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Gado de Leite

Universidade Estadual Paulista Júlio de Mesquita Filho Instituto de Biociências de Rio Claro

Universidade Estadual do Norte do Paraná (UENP) Departamento de Patologia Geral

Universidade Estadual Paulista Júlio de Mesquita Filho Instituto de Biociências de Rio Claro

Document Type Journal article
Language Portuguese
facebook logo  linkedin logo  twitter logo 
mendeley logo

Related documents