Detalhes do Documento

Fire resistance of cellular wooden slabs with rectangular and circular perforations

Autor(es): Couto, David ; Fonseca, E.M.M. ; Piloto, P.A.G. ; Meireles, J.M. ; Barreira, Luísa ; Ferreira, Débora

Data: 2015

Identificador Persistente: http://hdl.handle.net/10198/12804

Origem: Biblioteca Digital da UPB

Assunto(s): Cellular Wooden Slab; Perforation; Fire


Descrição

This work presents a numerical approach in arder to predict the behaviour and the perfonnance of typical cellular wooden slabs with rectangular and circular perforations when submitted to fire conditions. For this purpose a 3D numerical model was validated with different experimental tests at real scale obtained in laboratory m four cellular wooden slabs. This study was conducted in accordance with European standard EN 1365-2 and using a fire resistance íümace which complies the requirements ofEN 1363-1. The thermal perfomiance of the slab and the charring rate of the exposed siiïface will be compared for each type of perforations.

Tipo de Documento Objeto de conferência
Idioma Inglês
Contribuidor(es) Biblioteca Digital da UPB
Licença CC