The role of optic nerve sheath ultrasonography in increased intracranial pressure: a systematic review and meta analysis

Autor(es): Berhanu, David ; Cardoso Ferreira, Joana ; Pinto, Luis ; de Sousa, Diana Aguiar ; Lucas Neto, Lia ; Tavares Ferreira, Joana

Data: 2023

Identificador Persistente: http://hdl.handle.net/10451/61686

Origem: Repositório da Universidade de Lisboa

Assunto(s): Intracranial pressure; Optic nerve sheath; Optic nerve sheath diameter; Ultrasonography


Descrição

Objectives: To review the optimal diagnostic cut-off of ultrasonographic optic nerve sheath diameter (ONSD) in the diagnosis of increased intracranial pressure (IICP). Methods: A systematic search was conducted of available studies assessing the use of ONSD ultrasonography in patients with suspected IICP. Meta-analysis of diagnostic accuracy of ultrasonographic ONSD was performed using a bivariate model of random effects to summarize pooled sensitivity and specificity. A summary receiver operating characteristics (SROC) curve was plotted. Accuracy measures associated with ONSD cut-off and predefined covariates were investigated with meta-regression. Results: We included 38 studies, comprising a total of 2824 patients. A total of 21 studies used invasive techniques as a reference standard estimation of IICP and meta-analysis revealed a pooled sensitivity of 0.90 (95% CI 0.85-0.93) and specificity of 0.87 (95% CI 0.80-0.91). Optimal ONSD cut-off values ranged between 4.1 mm and 7.2 mm. Meta-regression analysis showed that ONSD cut-off values of 5.6 to 6.3 mm were associated with higher pooled specificity compared to cut-off values of 4.9 to 5.5 mm (0.93, 95% CI 0.85-0.97 vs. 0.78, 95% CI 0.65-0.87; p = 0.036). Conclusions: Ultrasonography of ONSD shows a high diagnostic accuracy for IICP, with high pooled sensitivity and specificity. Additionally, larger cut-off values seem to significantly increase specificity without compromising sensitivity, which support their use as optimal ONSD cut-off. The overall high sensitivity of ultrasonographic ONSD suggests its usefulness as a screening tool for IIC, which may provide an estimate of when invasive methods are warranted. Clinical relevance: ONSD ultrasonography is a fast and cost-effective method with a high diagnostic accuracy to detect IICP. The optimum ONSD cut-off hasn't been established before, but we suggest the 5.6 to 6.3 mm range as the best for the diagnosis of IICP.

Tipo de Documento Artigo científico
Idioma Inglês
Contribuidor(es) Repositório Científico de Acesso Aberto da ULisboa
Licença CC
facebook logo  linkedin logo  twitter logo 
mendeley logo

Documentos Relacionados