Resumo:This paper presents a comprehensive study towards the determination of efficient pole-arc coefficients for axial flux permanent magnet (PM) machines, through investigation of the contribution of volume elements of PMs to the no load flux linkage. The proposed methodology involves the evaluation of flux linkage using a mathematical expression which integrates a function over the volume of PMs instead of the classical integration of the magnetic flux density over the coil surface. The process is implemented using 2D finite element (FE) analysis, and the results shows the pole-arc coefficients that maximize the ratio of the flux linkage over the PM volume is between 0.5 and 0.6.
Autores principais:Ferreira, Ângela P.
Outros Autores:Costa, A.F.
Assunto:Axial flux machines Finite-element analysis No load flux linkage Pole-arc coefficient
Ano:2011
País:Portugal
Tipo de documento:comunicação em conferência
Tipo de acesso:acesso restrito
Instituição associada:Instituto Politécnico de Bragança
Idioma:inglês
Origem:Biblioteca Digital do IPB
_version_ 1867172977985978368
author Ferreira, Ângela P.
author2 Costa, A.F.
author2_role author
author_facet Ferreira, Ângela P.
Costa, A.F.
author_role author
contributor_name_str_mv Biblioteca Digital do IPB
country_str PT
creators_json_txt [{\"Person.name\":\"Ferreira, Ângela P.\",\"Person.identifier.orcid\":\"0000-0002-1912-2556\"},{\"Person.name\":\"Costa, A.F.\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Biblioteca Digital do IPB
datacite.creators.creator.creatorName.fl_str_mv Ferreira, Ângela P.
Costa, A.F.
datacite.date.Accepted.fl_str_mv 2011-01-01T00:00:00Z
datacite.date.available.fl_str_mv 2012-07-03T10:59:32Z
datacite.date.embargoed.fl_str_mv 2012-07-03T10:59:32Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_16ec
datacite.subjects.subject.fl_str_mv Axial flux machines
Finite-element analysis
No load flux linkage
Pole-arc coefficient
datacite.titles.title.fl_str_mv Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
dc.contributor.none.fl_str_mv Biblioteca Digital do IPB
dc.creator.none.fl_str_mv Ferreira, Ângela P.
Costa, A.F.
dc.date.Accepted.fl_str_mv 2011-01-01T00:00:00Z
dc.date.available.fl_str_mv 2012-07-03T10:59:32Z
dc.date.embargoed.fl_str_mv 2012-07-03T10:59:32Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://hdl.handle.net/10198/7117
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv IEEE
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_16ec
dc.subject.none.fl_str_mv Axial flux machines
Finite-element analysis
No load flux linkage
Pole-arc coefficient
dc.title.fl_str_mv Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_5794
description This paper presents a comprehensive study towards the determination of efficient pole-arc coefficients for axial flux permanent magnet (PM) machines, through investigation of the contribution of volume elements of PMs to the no load flux linkage. The proposed methodology involves the evaluation of flux linkage using a mathematical expression which integrates a function over the volume of PMs instead of the classical integration of the magnetic flux density over the coil surface. The process is implemented using 2D finite element (FE) analysis, and the results shows the pole-arc coefficients that maximize the ratio of the flux linkage over the PM volume is between 0.5 and 0.6.
dirty 0
eu_rights_str_mv restrictedAccess
format conferencePaper
fulltext.url.fl_str_mv https://bibliotecadigital.ipb.pt/bitstreams/38010636-9e00-4dbf-833a-33a7e0bcb8e6/download
id ipb_28f963fc65d9b705d6ac8eb76756eebb
identifier.url.fl_str_mv http://hdl.handle.net/10198/7117
instacron_str ipb
institution Instituto Politécnico de Bragança
instname_str Instituto Politécnico de Bragança
language eng
network_acronym_str ipb
network_name_str Biblioteca Digital do IPB
oai_identifier_str oai:bibliotecadigital.ipb.pt:10198/7117
organization_str_mv urn:organizationAcronym:ipb
person_str_mv Ferreira, Ângela P.
Ferreira, Ângela P.
https://www.ciencia-id.pt/2211-6787-D936
2211-6787-D936
http://orcid.org/0000-0002-1912-2556
0000-0002-1912-2556
Costa, A.F.
publishDate 2011
publisher.none.fl_str_mv IEEE
reponame_str Biblioteca Digital do IPB
repository_id_str urn:repositoryAcronym:ipb
service_str_mv urn:repositoryAcronym:ipb
spelling engIEEEporThis paper presents a comprehensive study towards the determination of efficient pole-arc coefficients for axial flux permanent magnet (PM) machines, through investigation of the contribution of volume elements of PMs to the no load flux linkage. The proposed methodology involves the evaluation of flux linkage using a mathematical expression which integrates a function over the volume of PMs instead of the classical integration of the magnetic flux density over the coil surface. The process is implemented using 2D finite element (FE) analysis, and the results shows the pole-arc coefficients that maximize the ratio of the flux linkage over the PM volume is between 0.5 and 0.6.application/pdfporEfficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machinesPersonalFerreira, Ângela P.DSpacehttp://dspace.org/items/3fec941d-79fb-4901-918d-a34ffa0195ccDSpacehttp://dspace.org/items/3fec941d-79fb-4901-918d-a34ffa0195ccFerreiraÂngela P.Ciência IDhttps://www.ciencia-id.pt2211-6787-D936ORCIDhttp://orcid.org0000-0002-1912-2556Researcher IDhttps://www.researcherid.comM-8188-2013Scopus Author IDhttps://www.scopus.com55516840300Costa, A.F.HostingInstitutionOrganizationalBiblioteca Digital do IPBe-mailmailto:dspace@ipb.ptdspace@ipb.ptISBNIsPartOf978-1-4244-9302-9URNIsPartOfIEEE Catalog Number: CFP11SDE-USB2012-07-03T10:59:32Z20112011-01-01T00:00:00ZHandlehttp://hdl.handle.net/10198/7117http://purl.org/coar/access_right/c_16ecrestricted accessAxial flux machinesFinite-element analysisNo load flux linkagePole-arc coefficient249403 bytesother research producthttp://purl.org/coar/resource_type/c_5794conference paperhttp://purl.org/coar/access_right/c_16ecapplication/pdffulltexthttps://bibliotecadigital.ipb.pt/bitstreams/38010636-9e00-4dbf-833a-33a7e0bcb8e6/download8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives (SDEMPED’2011)Bologna, Italy
spellingShingle Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
Ferreira, Ângela P.
Axial flux machines
Finite-element analysis
No load flux linkage
Pole-arc coefficient
status SINGLETON
subject.fl_str_mv Axial flux machines
Finite-element analysis
No load flux linkage
Pole-arc coefficient
title Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
title_full Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
title_fullStr Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
title_full_unstemmed Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
title_short Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
title_sort Efficient pole-arc coefficients for maximum no load flux linkage in axial flux permanent magnet machines
topic Axial flux machines
Finite-element analysis
No load flux linkage
Pole-arc coefficient
topic_facet Axial flux machines
Finite-element analysis
No load flux linkage
Pole-arc coefficient
url http://hdl.handle.net/10198/7117
visible 1