Direct driven axial flux permanent magnet generator for small-scale wind power applications

Ver documento

Detalhes bibliográficos
Resumo:The use of direct driven generators in small-scale wind power conversion systems, instead of geared machines, reduces the number of drive components, which offers the opportunity to reduce costs and increases system reliability and efficiency. For such applications, characterized by low speed of rotation, the axial flux permanent magnet generator is particularly suited, since it can be designed with a large pole number and high torque density.
Autores principais:Ferreira, Ângela P.
Outros Autores:Costa, A.F.
Ano:2011
País:Portugal
Tipo de documento:póster em conferência
Tipo de acesso:acesso aberto
Instituição associada:Instituto Politécnico de Bragança
Idioma:inglês
Origem:Biblioteca Digital do IPB
_version_ 1867173171314032640
author Ferreira, Ângela P.
author2 Costa, A.F.
author2_role author
author_facet Ferreira, Ângela P.
Costa, A.F.
author_role author
contributor_name_str_mv Biblioteca Digital do IPB
country_str PT
creators_json_txt [{\"Person.name\":\"Ferreira, Ângela P.\",\"Person.identifier.orcid\":\"0000-0002-1912-2556\"},{\"Person.name\":\"Costa, A.F.\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Biblioteca Digital do IPB
datacite.creators.creator.creatorName.fl_str_mv Ferreira, Ângela P.
Costa, A.F.
datacite.date.Accepted.fl_str_mv 2011-01-01T00:00:00Z
datacite.date.available.fl_str_mv 2014-10-20T08:40:06Z
datacite.date.embargoed.fl_str_mv 2014-10-20T08:40:06Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.titles.title.fl_str_mv Direct driven axial flux permanent magnet generator for small-scale wind power applications
dc.contributor.none.fl_str_mv Biblioteca Digital do IPB
dc.creator.none.fl_str_mv Ferreira, Ângela P.
Costa, A.F.
dc.date.Accepted.fl_str_mv 2011-01-01T00:00:00Z
dc.date.available.fl_str_mv 2014-10-20T08:40:06Z
dc.date.embargoed.fl_str_mv 2014-10-20T08:40:06Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://hdl.handle.net/10198/10891
dc.language.none.fl_str_mv eng
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.title.fl_str_mv Direct driven axial flux permanent magnet generator for small-scale wind power applications
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6670
description The use of direct driven generators in small-scale wind power conversion systems, instead of geared machines, reduces the number of drive components, which offers the opportunity to reduce costs and increases system reliability and efficiency. For such applications, characterized by low speed of rotation, the axial flux permanent magnet generator is particularly suited, since it can be designed with a large pole number and high torque density.
dirty 0
eu_rights_str_mv openAccess
format conferencePoster
fulltext.url.fl_str_mv https://bibliotecadigital.ipb.pt/bitstreams/4189f3ec-c4a0-4e2a-a88e-fff6270288d0/download
id ipb_cc9801ddfbb44d9d41b631175b4ffe83
identifier.url.fl_str_mv http://hdl.handle.net/10198/10891
instacron_str ipb
institution Instituto Politécnico de Bragança
instname_str Instituto Politécnico de Bragança
language eng
network_acronym_str ipb
network_name_str Biblioteca Digital do IPB
oai_identifier_str oai:bibliotecadigital.ipb.pt:10198/10891
organization_str_mv urn:organizationAcronym:ipb
person_str_mv Ferreira, Ângela P.
Ferreira, Ângela P.
https://www.ciencia-id.pt/2211-6787-D936
2211-6787-D936
http://orcid.org/0000-0002-1912-2556
0000-0002-1912-2556
Costa, A.F.
publishDate 2011
reponame_str Biblioteca Digital do IPB
repository_id_str urn:repositoryAcronym:ipb
service_str_mv urn:repositoryAcronym:ipb
spelling engporThe use of direct driven generators in small-scale wind power conversion systems, instead of geared machines, reduces the number of drive components, which offers the opportunity to reduce costs and increases system reliability and efficiency. For such applications, characterized by low speed of rotation, the axial flux permanent magnet generator is particularly suited, since it can be designed with a large pole number and high torque density.application/pdfporDirect driven axial flux permanent magnet generator for small-scale wind power applicationsPersonalFerreira, Ângela P.DSpacehttp://dspace.org/items/3fec941d-79fb-4901-918d-a34ffa0195ccDSpacehttp://dspace.org/items/3fec941d-79fb-4901-918d-a34ffa0195ccFerreiraÂngela P.Ciência IDhttps://www.ciencia-id.pt2211-6787-D936ORCIDhttp://orcid.org0000-0002-1912-2556Researcher IDhttps://www.researcherid.comM-8188-2013Scopus Author IDhttps://www.scopus.com55516840300Costa, A.F.HostingInstitutionOrganizationalBiblioteca Digital do IPBe-mailmailto:dspace@ipb.ptdspace@ipb.pt2014-10-20T08:40:06Z20112011-01-01T00:00:00ZHandlehttp://hdl.handle.net/10198/10891http://purl.org/coar/access_right/c_abf2open access2336377 bytesother research producthttp://purl.org/coar/resource_type/c_6670conference posterhttp://purl.org/coar/access_right/c_abf2application/pdffulltexthttps://bibliotecadigital.ipb.pt/bitstreams/4189f3ec-c4a0-4e2a-a88e-fff6270288d0/downloadInternational Conference on Renewable Energies and Power Quality, ICREPQ'11Las Palmas de Gran Canaria, Spain
spellingShingle Direct driven axial flux permanent magnet generator for small-scale wind power applications
Ferreira, Ângela P.
status SINGLETON
title Direct driven axial flux permanent magnet generator for small-scale wind power applications
title_full Direct driven axial flux permanent magnet generator for small-scale wind power applications
title_fullStr Direct driven axial flux permanent magnet generator for small-scale wind power applications
title_full_unstemmed Direct driven axial flux permanent magnet generator for small-scale wind power applications
title_short Direct driven axial flux permanent magnet generator for small-scale wind power applications
title_sort Direct driven axial flux permanent magnet generator for small-scale wind power applications
url http://hdl.handle.net/10198/10891
visible 1