Resumo:A membrane ozone contactor, operated under continuous mode, was applied to promote the tertiary treatment of urban wastewater (UWW), targeting the removal of contaminants of emerging concern (CECs), bacterial disinfection, and toxicity reduction. This system relies on the homogeneous radial distribution of ozone (O3) in the reaction zone by "titration" through a microfiltration borosilicate tubular membrane, while the UWW swirls around the membrane and drags the O3 microbubbles generated in the membrane shell-side. The membrane is coated with titanium dioxide (TiO2-P25) and radiation can be externally supplied via four UV lamps. The ozonation tests were carried out with secondary-treated UWW collected in different seasons (winter and summer) and spiked with a mix of 19 CECs (10 & mu;g L-1 each). For an O3 dose of 18 g m-3, the best performance was obtained by increasing the O3 concentration (maximum [O3]G,inlet of 200 g Nm-3) and decreasing the gas flow rate (minimum QG of 0.15 Ndm3 min-1), providing the highest ozone transfer yield (88 %) and, thus higher specific ozone dose (g O3 per g dissolved organic carbon). Under these conditions, removals >80 % or concentrations below the limit of quantification were obtained for up to 13 of the 19 CECs and reductions up to 5 log units for total heterotrophs and below the limit of detection for enterobacteria and enterococci. Tests including a UVC dose of 0.10 kJ L-1 enhanced disinfection ability but had no impact on CECs oxidation. After ozonation, the abundance of antibiotic resistant bacteria was reduced but not elimi-nated , microbial regrowth after 3-day storage was observed. No toxic effect was detected on zebrafish embryos using a dilution factor of 4 for the ozonized UWW , when granular activated carbon adsorption was subsequently applied the dilution factor decreased to 2.
Autores principais:Presumido, Pedro Henrique
Outros Autores:Ribeirinho-Soares, Sara; Montes, Rosa; Quintana, Jose B.; Rodil, Rosário; Ribeiro, Marta; Neuparth, Teresa; Santos, Miguel M.; Feliciano, Manuel; Nunes, Olga C.; Gomes, Ana I.; Vilar, Vítor J.P.
Assunto:Contaminants of emerging concern Disinfection Ozonation Ozone membrane contactor Zebrafish embryos bioassays
Ano:2023
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Instituto Politécnico de Bragança
Idioma:inglês
Origem:Biblioteca Digital do IPB
_version_ 1867172904127430656
author Presumido, Pedro Henrique
author2 Ribeirinho-Soares, Sara
Montes, Rosa
Quintana, Jose B.
Rodil, Rosário
Ribeiro, Marta
Neuparth, Teresa
Santos, Miguel M.
Feliciano, Manuel
Nunes, Olga C.
Gomes, Ana I.
Vilar, Vítor J.P.
author2_role author
author
author
author
author
author
author
author
author
author
author
author_facet Presumido, Pedro Henrique
Ribeirinho-Soares, Sara
Montes, Rosa
Quintana, Jose B.
Rodil, Rosário
Ribeiro, Marta
Neuparth, Teresa
Santos, Miguel M.
Feliciano, Manuel
Nunes, Olga C.
Gomes, Ana I.
Vilar, Vítor J.P.
author_role author
contributor_name_str_mv Biblioteca Digital do IPB
country_str PT
creators_json_txt [{\"Person.name\":\"Presumido, Pedro Henrique\"},{\"Person.name\":\"Ribeirinho-Soares, Sara\"},{\"Person.name\":\"Montes, Rosa\"},{\"Person.name\":\"Quintana, Jose B.\"},{\"Person.name\":\"Rodil, Rosário\"},{\"Person.name\":\"Ribeiro, Marta\"},{\"Person.name\":\"Neuparth, Teresa\"},{\"Person.name\":\"Santos, Miguel M.\"},{\"Person.name\":\"Feliciano, Manuel\",\"Person.identifier.orcid\":\"0000-0002-3147-4511\"},{\"Person.name\":\"Nunes, Olga C.\"},{\"Person.name\":\"Gomes, Ana I.\"},{\"Person.name\":\"Vilar, Vítor J.P.\"}]
datacite.contributors.contributor.contributorName.fl_str_mv Biblioteca Digital do IPB
datacite.creators.creator.creatorName.fl_str_mv Presumido, Pedro Henrique
Ribeirinho-Soares, Sara
Montes, Rosa
Quintana, Jose B.
Rodil, Rosário
Ribeiro, Marta
Neuparth, Teresa
Santos, Miguel M.
Feliciano, Manuel
Nunes, Olga C.
Gomes, Ana I.
Vilar, Vítor J.P.
datacite.date.Accepted.fl_str_mv 2023-01-01T00:00:00Z
datacite.date.available.fl_str_mv 2014-10-08T09:05:03Z
datacite.date.embargoed.fl_str_mv 2014-10-08T09:05:03Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_abf2
datacite.subjects.subject.fl_str_mv Contaminants of emerging concern
Disinfection
Ozonation
Ozone membrane contactor
Zebrafish embryos bioassays
datacite.titles.title.fl_str_mv Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
dc.contributor.none.fl_str_mv Biblioteca Digital do IPB
dc.creator.none.fl_str_mv Presumido, Pedro Henrique
Ribeirinho-Soares, Sara
Montes, Rosa
Quintana, Jose B.
Rodil, Rosário
Ribeiro, Marta
Neuparth, Teresa
Santos, Miguel M.
Feliciano, Manuel
Nunes, Olga C.
Gomes, Ana I.
Vilar, Vítor J.P.
dc.date.Accepted.fl_str_mv 2023-01-01T00:00:00Z
dc.date.available.fl_str_mv 2014-10-08T09:05:03Z
dc.date.embargoed.fl_str_mv 2014-10-08T09:05:03Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://hdl.handle.net/10198/10744
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Elsevier
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.subject.none.fl_str_mv Contaminants of emerging concern
Disinfection
Ozonation
Ozone membrane contactor
Zebrafish embryos bioassays
dc.title.fl_str_mv Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description A membrane ozone contactor, operated under continuous mode, was applied to promote the tertiary treatment of urban wastewater (UWW), targeting the removal of contaminants of emerging concern (CECs), bacterial disinfection, and toxicity reduction. This system relies on the homogeneous radial distribution of ozone (O3) in the reaction zone by "titration" through a microfiltration borosilicate tubular membrane, while the UWW swirls around the membrane and drags the O3 microbubbles generated in the membrane shell-side. The membrane is coated with titanium dioxide (TiO2-P25) and radiation can be externally supplied via four UV lamps. The ozonation tests were carried out with secondary-treated UWW collected in different seasons (winter and summer) and spiked with a mix of 19 CECs (10 & mu;g L-1 each). For an O3 dose of 18 g m-3, the best performance was obtained by increasing the O3 concentration (maximum [O3]G,inlet of 200 g Nm-3) and decreasing the gas flow rate (minimum QG of 0.15 Ndm3 min-1), providing the highest ozone transfer yield (88 %) and, thus higher specific ozone dose (g O3 per g dissolved organic carbon). Under these conditions, removals >80 % or concentrations below the limit of quantification were obtained for up to 13 of the 19 CECs and reductions up to 5 log units for total heterotrophs and below the limit of detection for enterobacteria and enterococci. Tests including a UVC dose of 0.10 kJ L-1 enhanced disinfection ability but had no impact on CECs oxidation. After ozonation, the abundance of antibiotic resistant bacteria was reduced but not elimi-nated , microbial regrowth after 3-day storage was observed. No toxic effect was detected on zebrafish embryos using a dilution factor of 4 for the ozonized UWW , when granular activated carbon adsorption was subsequently applied the dilution factor decreased to 2.
dirty 0
eu_rights_str_mv openAccess
format article
fulltext.url.fl_str_mv https://bibliotecadigital.ipb.pt/bitstreams/89e5472c-ac0a-465c-a762-2f709b483e0e/download
id ipb_dc9e7a065aa4fce36e4a0b43fa31fb86
identifier.url.fl_str_mv http://hdl.handle.net/10198/10744
instacron_str ipb
institution Instituto Politécnico de Bragança
instname_str Instituto Politécnico de Bragança
language eng
network_acronym_str ipb
network_name_str Biblioteca Digital do IPB
oai_identifier_str oai:bibliotecadigital.ipb.pt:10198/10744
organization_str_mv urn:organizationAcronym:ipb
person_str_mv Presumido, Pedro Henrique
Ribeirinho-Soares, Sara
Montes, Rosa
Quintana, Jose B.
Rodil, Rosário
Ribeiro, Marta
Neuparth, Teresa
Santos, Miguel M.
Feliciano, Manuel
Feliciano, Manuel
https://www.ciencia-id.pt/2D11-7230-702B
2D11-7230-702B
http://orcid.org/0000-0002-3147-4511
0000-0002-3147-4511
Nunes, Olga C.
Gomes, Ana I.
Vilar, Vítor J.P.
publishDate 2023
publisher.none.fl_str_mv Elsevier
reponame_str Biblioteca Digital do IPB
repository_id_str urn:repositoryAcronym:ipb
service_str_mv urn:repositoryAcronym:ipb
spelling engElsevierporA membrane ozone contactor, operated under continuous mode, was applied to promote the tertiary treatment of urban wastewater (UWW), targeting the removal of contaminants of emerging concern (CECs), bacterial disinfection, and toxicity reduction. This system relies on the homogeneous radial distribution of ozone (O3) in the reaction zone by "titration" through a microfiltration borosilicate tubular membrane, while the UWW swirls around the membrane and drags the O3 microbubbles generated in the membrane shell-side. The membrane is coated with titanium dioxide (TiO2-P25) and radiation can be externally supplied via four UV lamps. The ozonation tests were carried out with secondary-treated UWW collected in different seasons (winter and summer) and spiked with a mix of 19 CECs (10 & mu;g L-1 each). For an O3 dose of 18 g m-3, the best performance was obtained by increasing the O3 concentration (maximum [O3]G,inlet of 200 g Nm-3) and decreasing the gas flow rate (minimum QG of 0.15 Ndm3 min-1), providing the highest ozone transfer yield (88 %) and, thus higher specific ozone dose (g O3 per g dissolved organic carbon). Under these conditions, removals >80 % or concentrations below the limit of quantification were obtained for up to 13 of the 19 CECs and reductions up to 5 log units for total heterotrophs and below the limit of detection for enterobacteria and enterococci. Tests including a UVC dose of 0.10 kJ L-1 enhanced disinfection ability but had no impact on CECs oxidation. After ozonation, the abundance of antibiotic resistant bacteria was reduced but not elimi-nated , microbial regrowth after 3-day storage was observed. No toxic effect was detected on zebrafish embryos using a dilution factor of 4 for the ozonized UWW , when granular activated carbon adsorption was subsequently applied the dilution factor decreased to 2.application/pdfporOzone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessmentPresumido, Pedro HenriqueRibeirinho-Soares, SaraMontes, RosaQuintana, Jose B.Rodil, RosárioRibeiro, MartaNeuparth, TeresaSantos, Miguel M.PersonalFeliciano, ManuelDSpacehttp://dspace.org/items/ccb9c69d-2820-493b-ab44-77b0538814faDSpacehttp://dspace.org/items/ccb9c69d-2820-493b-ab44-77b0538814faFelicianoManuelCiência IDhttps://www.ciencia-id.pt2D11-7230-702BORCIDhttp://orcid.org0000-0002-3147-4511Scopus Author IDhttps://www.scopus.com6603358480Nunes, Olga C.Gomes, Ana I.Vilar, Vítor J.P.HostingInstitutionOrganizationalBiblioteca Digital do IPBe-mailmailto:dspace@ipb.ptdspace@ipb.ptISSNIsPartOf0048-9697DOIIsPartOf10.1016/j.scitotenv.2023.1644922014-10-08T09:05:03Z20232023-01-01T00:00:00ZHandlehttp://hdl.handle.net/10198/10744http://purl.org/coar/access_right/c_abf2open accessContaminants of emerging concernDisinfectionOzonationOzone membrane contactorZebrafish embryos bioassays1794312 bytesliteraturehttp://purl.org/coar/resource_type/c_6501journal articlehttp://purl.org/coar/access_right/c_abf2application/pdffulltexthttps://bibliotecadigital.ipb.pt/bitstreams/89e5472c-ac0a-465c-a762-2f709b483e0e/downloadScience of The Total Environment
spellingShingle Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
Presumido, Pedro Henrique
Contaminants of emerging concern
Disinfection
Ozonation
Ozone membrane contactor
Zebrafish embryos bioassays
status SINGLETON
subject.fl_str_mv Contaminants of emerging concern
Disinfection
Ozonation
Ozone membrane contactor
Zebrafish embryos bioassays
title Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
title_full Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
title_fullStr Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
title_full_unstemmed Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
title_short Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
title_sort Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
topic Contaminants of emerging concern
Disinfection
Ozonation
Ozone membrane contactor
Zebrafish embryos bioassays
topic_facet Contaminants of emerging concern
Disinfection
Ozonation
Ozone membrane contactor
Zebrafish embryos bioassays
url http://hdl.handle.net/10198/10744
visible 1