Resumo:This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.
Autores principais:Seixas, Mafalda
Outros Autores:Melício, Rui; Mendes, Victor
Assunto:Offshore wind system HVDC light Four-level converter Unbalance capacitor voltage Rectifier malfunction Smart grid Simulation
Ano:2015
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso restrito
Instituição associada:Instituto Politécnico de Lisboa
Idioma:inglês
Origem:Repositório Científico do Instituto Politécnico de Lisboa
_version_ 1868417573038587904
author Seixas, Mafalda
author2 Melício, Rui
Mendes, Victor
author2_role author
author
author_facet Seixas, Mafalda
Melício, Rui
Mendes, Victor
author_role author
contributor_name_str_mv RCIPL
country_str PT
creators_json_txt [{\"Person.name\":\"Seixas, Mafalda\",\"Person.identifier.orcid\":\"0000-0002-8078-9317\"},{\"Person.name\":\"Melício, Rui\"},{\"Person.name\":\"Mendes, Victor\",\"Person.identifier.orcid\":\"0000-0002-4599-477X\"}]
datacite.contributors.contributor.contributorName.fl_str_mv RCIPL
datacite.creators.creator.creatorName.fl_str_mv Seixas, Mafalda
Melício, Rui
Mendes, Victor
datacite.date.Accepted.fl_str_mv 2015-06-01T00:00:00Z
datacite.date.available.fl_str_mv 2016-02-24T15:45:39Z
datacite.date.embargoed.fl_str_mv 2016-02-24T15:45:39Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_16ec
datacite.subjects.subject.fl_str_mv Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
datacite.titles.title.fl_str_mv Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
dc.contributor.none.fl_str_mv RCIPL
dc.creator.none.fl_str_mv Seixas, Mafalda
Melício, Rui
Mendes, Victor
dc.date.Accepted.fl_str_mv 2015-06-01T00:00:00Z
dc.date.available.fl_str_mv 2016-02-24T15:45:39Z
dc.date.embargoed.fl_str_mv 2016-02-24T15:45:39Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://hdl.handle.net/10400.21/5732
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Pergamon-Elsevier Science LTD
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_16ec
dc.subject.none.fl_str_mv Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
dc.title.fl_str_mv Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
description This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.
dirty 0
eu_rights_str_mv restrictedAccess
format article
fulltext.url.fl_str_mv https://repositorio.ipl.pt/bitstreams/37dd72fd-f364-412c-a84c-20ffc453c248/download
id ripl_fbd2fadb39eabc7f3259fe6a4eed542e
identifier.url.fl_str_mv http://hdl.handle.net/10400.21/5732
instacron_str ipl
institution Instituto Politécnico de Lisboa
instname_str Instituto Politécnico de Lisboa
language eng
network_acronym_str ripl
network_name_str Repositório Científico do Instituto Politécnico de Lisboa
oai_identifier_str oai:repositorio.ipl.pt:10400.21/5732
organization_str_mv urn:organizationAcronym:ipl
person_str_mv Seixas, Mafalda
Seixas, Mafalda
http://orcid.org/0000-0002-8078-9317
0000-0002-8078-9317
Melício, Rui
Mendes, Victor
Mendes, Victor
http://orcid.org/0000-0002-4599-477X
0000-0002-4599-477X
publishDate 2015
publisher.none.fl_str_mv Pergamon-Elsevier Science LTD
reponame_str Repositório Científico do Instituto Politécnico de Lisboa
repository_id_str urn:repositoryAcronym:ripl
service_str_mv urn:repositoryAcronym:ripl
spelling engPergamon-Elsevier Science LTDpt_PTThis paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.application/pdfpt_PTSimulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context toolPersonalSeixas, MafaldaDSpacehttp://dspace.org/items/622605ea-3c85-4994-8ada-9757a052aa12DSpacehttp://dspace.org/items/622605ea-3c85-4994-8ada-9757a052aa12SeixasMafaldaORCIDhttp://orcid.org0000-0002-8078-9317Scopus Author IDhttps://www.scopus.com56022242600Melício, RuiPersonalMendes, VictorDSpacehttp://dspace.org/items/a86b9291-f23c-4f09-83d7-9ee691696705DSpacehttp://dspace.org/items/a86b9291-f23c-4f09-83d7-9ee691696705MendesVictorORCIDhttp://orcid.org0000-0002-4599-477XResearcher IDhttps://www.researcherid.comD-2332-2012Scopus Author IDhttps://www.scopus.com55138675600HostingInstitutionOrganizationalRCIPLe-mailmailto:rcaap@sp.ipl.ptrcaap@sp.ipl.ptISSNIsPartOf0196-8904ISSNIsPartOf1879-2227DOIIsPartOf10.1016/j.enconman.2015.03.0502016-02-24T15:45:39Z2015-062015-06-01T00:00:00ZHandlehttp://hdl.handle.net/10400.21/5732http://purl.org/coar/access_right/c_16ecrestricted accessOffshore wind systemHVDC lightFour-level converterUnbalance capacitor voltageRectifier malfunctionSmart gridSimulation2419890 bytesliteraturehttp://purl.org/coar/resource_type/c_6501journal articlehttp://purl.org/coar/access_right/c_16ecapplication/pdffulltexthttps://repositorio.ipl.pt/bitstreams/37dd72fd-f364-412c-a84c-20ffc453c248/download97140153
spellingShingle Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
Seixas, Mafalda
Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
status SINGLETON
subject.fl_str_mv Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
title Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_full Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_fullStr Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_full_unstemmed Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_short Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_sort Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
topic Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
topic_facet Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
url http://hdl.handle.net/10400.21/5732
visible 1