Publicação
New method for measuring thickness in thin transparent medium
| Resumo: | The aim of this method is to determine the thickness of a transparent medium, close to the corneal thickness, using the angle at the first and second Purkinje images are aligned for a specific optical slit width. An optical slit is projected in an oblique angle relatively to the transparent medium, producing two different reflections in each medium surface (first and second Purkinje images). The slit is then moved until the first and second Purkinje images of the slit are aligned in such a way, that look as if they were a continuous slit. The slit width, the angle between the illumination and observation, and the medium index are used, then, to calculate the medium thickness. This method was implemented in a slit lamp and the central thicknesses (CT) of nine gas-permeable contact lenses (CL) were measured, with this method and a mechanical gauge and the results were compared. The mean CT difference ± standard deviation, between the two methods was 0.004 ± 0.008 mm with minimum and maximum absolute values of 0.002 and 0.019 mm. This technique showed good precision to measure the CT of CL and should be tried in human corneas. |
|---|---|
| Autores principais: | Sousa, Raul A. R. C. |
| Outros Autores: | Baptista, António M. G. |
| Assunto: | Corneal thickness Contact lens thickness Corneal topography Corneal pachometry |
| Ano: | 2011 |
| País: | Portugal |
| Tipo de documento: | comunicação em conferência |
| Tipo de acesso: | acesso restrito |
| Instituição associada: | Universidade do Minho |
| Idioma: | inglês |
| Origem: | RepositóriUM - Universidade do Minho |
Registos relacionados
article Changes in corneal structure with continuous wear of High-Dk Soft contact lenses: a pilot study
por: González-Méijome, José Manuel
Publicado em: (2003)
por: González-Méijome, José Manuel
Publicado em: (2003)
article Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor
por: González-Pérez, Javier
Publicado em: (2011)
por: González-Pérez, Javier
Publicado em: (2011)
article The thinnest, steepest, and maximum elevation Corneal locations in noncontact and contact lens wearers in keratoconus
por: Romero-Jimenez, Miguel
Publicado em: (2013)
por: Romero-Jimenez, Miguel
Publicado em: (2013)
article Central corneal thickness measured with three optical devices and ultrasound pachometry
por: González-Pérez, Javier
Publicado em: (2011)
por: González-Pérez, Javier
Publicado em: (2011)
article A pilot study on the influence of biomechanical properties of the cornea on short-term response to myopic corneal refractive therapy
por: González-Méijome, José Manuel
Publicado em: (2008)
por: González-Méijome, José Manuel
Publicado em: (2008)
school Alterações da espessura do reservatório lacrimal e na qualidade ótica ao longo de um dia de uso de lentes esclerais
por: Seco, Rita Maria Serra
Publicado em: (2023)
por: Seco, Rita Maria Serra
Publicado em: (2023)
article What intrinsic factors affect the central corneal thickness?
por: Silva, Filipe da
Publicado em: (2025)
por: Silva, Filipe da
Publicado em: (2025)
article Age-related variations in corneal asphericity and long-term changes
por: Amorim-de-Sousa, Ana
Publicado em: (2019)
por: Amorim-de-Sousa, Ana
Publicado em: (2019)
article Age differences in central and peripheral intra-ocular pressure using a rebound tonometer
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
por: González-Méijome, José Manuel
Publicado em: (2003)
por: González-Méijome, José Manuel
Publicado em: (2003)
article Correlations between corneal biomechanical properties measured with the ocular response analyzer and icare rebound tonometry
por: Jorge, Jorge
Publicado em: (2008)
por: Jorge, Jorge
Publicado em: (2008)
category Within and between session repeatability of topographic data using medmont E-300 corneal topographer
por: Fernandes, Paulo Rodrigues
Publicado em: (2005)
por: Fernandes, Paulo Rodrigues
Publicado em: (2005)
article Accuracy and repeatability of a new portable ultrasound pachymeter
por: Queirós, A.
Publicado em: (2007)
por: Queirós, A.
Publicado em: (2007)
article Technical Note: Accuracy and repeatability of a new portable ultrasound pachymeter
por: Queirós, A.
Publicado em: (2007)
por: Queirós, A.
Publicado em: (2007)
image Topographical changes in anterior corneal curvature after LASIK
por: González-Méijome, José Manuel
Publicado em: (2004)
por: González-Méijome, José Manuel
Publicado em: (2004)
article Relationship of placido corneal topography data with scleral lens fitting parameters
por: Macedo-de-Araújo, Rute J.
Publicado em: (2019)
por: Macedo-de-Araújo, Rute J.
Publicado em: (2019)
article Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
por: Rodrigues, Patrícia
Publicado em: (2015)
por: Rodrigues, Patrícia
Publicado em: (2015)
article Topographical irregularity and keratoconic findings in five siblings and their parents
por: González-Méijome, José Manuel
Publicado em: (2014)
por: González-Méijome, José Manuel
Publicado em: (2014)
article Comparison of central corneal thickness measured by standard ultrasound pachymetry, corneal topography, tono-pachymetry and anterior segment optical coherence tomography
por: González-Pérez, Javier
Publicado em: (2018)
por: González-Pérez, Javier
Publicado em: (2018)
article End-of-day dryness, corneal sensitivity and blink rate in contact lens wearers
por: Martín-Montañez, Vicente
Publicado em: (2015)
por: Martín-Montañez, Vicente
Publicado em: (2015)
article Correlations between central and peripheral changes in anterior corneal topography after myopic LASIK and their implications in postsurgical contact lens fitting
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article A comparison of the ARK-700A autokeratometer and medmont E300 corneal topographer when measuring peripheral corneal curvature
por: González-Méijome, José Manuel
Publicado em: (2004)
por: González-Méijome, José Manuel
Publicado em: (2004)
article Short-term corneal response to corneal refractive therapy for different refractive targets
por: Villa-Collar, Cesar
Publicado em: (2009)
por: Villa-Collar, Cesar
Publicado em: (2009)
article Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
por: Macedo-de-Araújo, Rute J.
Publicado em: (2023)
por: Macedo-de-Araújo, Rute J.
Publicado em: (2023)
article Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpfug tomography and ultrasound
por: Jorge, Jorge
Publicado em: (2013)
por: Jorge, Jorge
Publicado em: (2013)
article Anterior and posterior corneal elevation after orthokeratology and standard and customized LASIK surgery
por: Queirós, A.
Publicado em: (2011)
por: Queirós, A.
Publicado em: (2011)
school The use of biomaterials in the treatment of deep corneal lesions in small animals
por: Vidal, Miguel Frederico Pimenta de Carvalho Perry
Publicado em: (2020)
por: Vidal, Miguel Frederico Pimenta de Carvalho Perry
Publicado em: (2020)
category Ectasia detection by the assessment of corneal biomechanics
por: Ambrósio Jr., Renato
Publicado em: (2016)
por: Ambrósio Jr., Renato
Publicado em: (2016)
article Determination of oxygen permeability in soft contact lenses using a polarographic method : estimation of relevant physiological parameters
por: González-Méijome, José Manuel
Publicado em: (2008)
por: González-Méijome, José Manuel
Publicado em: (2008)
article Effect of pupil size on corneal aberrations before and after standard, custom LASIK and corneal refractive therapy
por: Queirós, A.
Publicado em: (2010)
por: Queirós, A.
Publicado em: (2010)
article Refractive, biometric and corneal topographic parameter changes during 12 months of orthokeratology
por: Queirós, A.
Publicado em: (2020)
por: Queirós, A.
Publicado em: (2020)
article Improvement of vision and ocular surface symptoms with a scleral lens after microbial keratitis
por: Macedo-de-Araujo, Rute J.
Publicado em: (2021)
por: Macedo-de-Araujo, Rute J.
Publicado em: (2021)
article Comfort and vision scores at insertion and removal during 1 month of wear of paragon CRT for corneal reshaping
por: González-Méijome, José Manuel
Publicado em: (2011)
por: González-Méijome, José Manuel
Publicado em: (2011)
article Multi-aspheric description of the myopic cornea after different refractive treatments and its correlation with corneal higher order aberrations
por: Queirós, A.
Publicado em: (2012)
por: Queirós, A.
Publicado em: (2012)
article Changes in choroidal thickness and retinal activity with a myopia control contact lens
por: Amorim-de-Sousa, Ana
Publicado em: (2023)
por: Amorim-de-Sousa, Ana
Publicado em: (2023)
article Daily versus monthly disposable contact lens: Which is better for ocular surface physiology and comfort?
por: Sapkota, Kishor
Publicado em: (2018)
por: Sapkota, Kishor
Publicado em: (2018)
image Where does ARK-700A actually measures peripheral corneal curvature? A comparison with medmont videokeratoscope
por: González-Méijome, José Manuel
Publicado em: (2003)
por: González-Méijome, José Manuel
Publicado em: (2003)
article CLEAR-Orthokeratology
por: Vincent, Stephen J.
Publicado em: (2021)
por: Vincent, Stephen J.
Publicado em: (2021)
school Edema corneal com lentes esclerais
por: Oliveira, Cristina Daniela Moreira
Publicado em: (2013)
por: Oliveira, Cristina Daniela Moreira
Publicado em: (2013)
article Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract
por: Faria-Correia, Fernando
Publicado em: (2016)
por: Faria-Correia, Fernando
Publicado em: (2016)
Registos relacionados
-
article Changes in corneal structure with continuous wear of High-Dk Soft contact lenses: a pilot study
por: González-Méijome, José Manuel
Publicado em: (2003) -
article Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor
por: González-Pérez, Javier
Publicado em: (2011) -
article The thinnest, steepest, and maximum elevation Corneal locations in noncontact and contact lens wearers in keratoconus
por: Romero-Jimenez, Miguel
Publicado em: (2013) -
article Central corneal thickness measured with three optical devices and ultrasound pachometry
por: González-Pérez, Javier
Publicado em: (2011) -
article A pilot study on the influence of biomechanical properties of the cornea on short-term response to myopic corneal refractive therapy
por: González-Méijome, José Manuel
Publicado em: (2008)