Publicação
Age-related variations in corneal asphericity and long-term changes
| Resumo: | Purpose: Corneal front-surface asphericity is directly related with the optical quality of the eye and with contact lenses fitting. The purpose of this study was to evaluate the corneal asphericity as a function of age, sex, and refractive error measured with autokeratometry and corneal topography and its long-term changes (5- to 10-year period). Methods: The asphericity and corneal curvature were obtained with the autorefractometer/autokeratometer NIDEK ARK-700A and with the videokeratoscope MODI 2.0 and compared. Corneal asphericity was retrospectively analyzed with NIDEK ARK-700A. The longitudinal study of asphericity was conducted with the same device between 2 appointments within an interval of 5 to 10 years. Results: NIDEK ARK-700A showed agreement of asphericity values with those of MODI 2.0 (P¼0.172) for a 7-mm diameter chord. The mean Q value of 1,484 right eyes (58.6% female), with a mean age of 40.2618.4 years, was 20.2460.12. No differences were found for Q value between sexes (P¼0.424), age groups (P¼0.268), and refractive error groups (P¼0.107). The longitudinal analysis of corneal asphericity in 190 eyes (62.1% female) over a mean period of 5.961.4 years showed no significant differences in the Q value (0.0060.08, P¼0.813) over time. However, 14% showed asphericity changes of 60.10 or higher while 86% of the subjects showed a change below 60.10. Conclusions: The mean Q value observed in this study agrees with the average values of a white population and contributes to slightly reduce the positive spherical aberration of the eye. For the large majority of this population, the asphericity did not show significant changes within a period of 5 to 10 years, but significant changes can be observed in some patients. |
|---|---|
| Autores principais: | Amorim-de-Sousa, Ana |
| Outros Autores: | Vieira, Ana Cláudia; González-Méijome, José Manuel; Queirós, A. |
| Assunto: | Corneal topography Corneal asphericity Corneal curvature Corneal changes |
| Ano: | 2019 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso restrito |
| Instituição associada: | Universidade do Minho |
| Idioma: | inglês |
| Origem: | RepositóriUM - Universidade do Minho |
Registos relacionados
article Multi-aspheric description of the myopic cornea after different refractive treatments and its correlation with corneal higher order aberrations
por: Queirós, A.
Publicado em: (2012)
por: Queirós, A.
Publicado em: (2012)
image Topographical changes in anterior corneal curvature after LASIK
por: González-Méijome, José Manuel
Publicado em: (2004)
por: González-Méijome, José Manuel
Publicado em: (2004)
category Within and between session repeatability of topographic data using medmont E-300 corneal topographer
por: Fernandes, Paulo Rodrigues
Publicado em: (2005)
por: Fernandes, Paulo Rodrigues
Publicado em: (2005)
article New method for measuring thickness in thin transparent medium
por: Sousa, Raul A. R. C.
Publicado em: (2011)
por: Sousa, Raul A. R. C.
Publicado em: (2011)
article A pilot study on the influence of biomechanical properties of the cornea on short-term response to myopic corneal refractive therapy
por: González-Méijome, José Manuel
Publicado em: (2008)
por: González-Méijome, José Manuel
Publicado em: (2008)
article Correlations between central and peripheral changes in anterior corneal topography after myopic LASIK and their implications in postsurgical contact lens fitting
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Short-term corneal response to corneal refractive therapy for different refractive targets
por: Villa-Collar, Cesar
Publicado em: (2009)
por: Villa-Collar, Cesar
Publicado em: (2009)
image Where does ARK-700A actually measures peripheral corneal curvature? A comparison with medmont videokeratoscope
por: González-Méijome, José Manuel
Publicado em: (2003)
por: González-Méijome, José Manuel
Publicado em: (2003)
school The use of biomaterials in the treatment of deep corneal lesions in small animals
por: Vidal, Miguel Frederico Pimenta de Carvalho Perry
Publicado em: (2020)
por: Vidal, Miguel Frederico Pimenta de Carvalho Perry
Publicado em: (2020)
school Primary corneal endothelial degeneration in dogs retrospectiive study of 30 cases
por: Miranda, Rita Cacho
Publicado em: (2019)
por: Miranda, Rita Cacho
Publicado em: (2019)
article Anterior and posterior corneal elevation after orthokeratology and standard and customized LASIK surgery
por: Queirós, A.
Publicado em: (2011)
por: Queirós, A.
Publicado em: (2011)
article A comparison of the ARK-700A autokeratometer and medmont E300 corneal topographer when measuring peripheral corneal curvature
por: González-Méijome, José Manuel
Publicado em: (2004)
por: González-Méijome, José Manuel
Publicado em: (2004)
article Refractive, biometric and corneal topographic parameter changes during 12 months of orthokeratology
por: Queirós, A.
Publicado em: (2020)
por: Queirós, A.
Publicado em: (2020)
article Effect of pupil size on corneal aberrations before and after standard, custom LASIK and corneal refractive therapy
por: Queirós, A.
Publicado em: (2010)
por: Queirós, A.
Publicado em: (2010)
category Ectasia detection by the assessment of corneal biomechanics
por: Ambrósio Jr., Renato
Publicado em: (2016)
por: Ambrósio Jr., Renato
Publicado em: (2016)
article Topographical irregularity and keratoconic findings in five siblings and their parents
por: González-Méijome, José Manuel
Publicado em: (2014)
por: González-Méijome, José Manuel
Publicado em: (2014)
article What intrinsic factors affect the central corneal thickness?
por: Silva, Filipe da
Publicado em: (2025)
por: Silva, Filipe da
Publicado em: (2025)
article Correlations between corneal biomechanical properties measured with the ocular response analyzer and icare rebound tonometry
por: Jorge, Jorge
Publicado em: (2008)
por: Jorge, Jorge
Publicado em: (2008)
article Changes in corneal structure with continuous wear of High-Dk Soft contact lenses: a pilot study
por: González-Méijome, José Manuel
Publicado em: (2003)
por: González-Méijome, José Manuel
Publicado em: (2003)
article Age differences in central and peripheral intra-ocular pressure using a rebound tonometer
por: González-Méijome, José Manuel
Publicado em: (2006)
por: González-Méijome, José Manuel
Publicado em: (2006)
article Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpfug tomography and ultrasound
por: Jorge, Jorge
Publicado em: (2013)
por: Jorge, Jorge
Publicado em: (2013)
article Dynamic corneal deformation response and integrated corneal tomography
por: Salomão, Marcella Q.
Publicado em: (2018)
por: Salomão, Marcella Q.
Publicado em: (2018)
article Relationship of placido corneal topography data with scleral lens fitting parameters
por: Macedo-de-Araújo, Rute J.
Publicado em: (2019)
por: Macedo-de-Araújo, Rute J.
Publicado em: (2019)
school Alterações da espessura do reservatório lacrimal e na qualidade ótica ao longo de um dia de uso de lentes esclerais
por: Seco, Rita Maria Serra
Publicado em: (2023)
por: Seco, Rita Maria Serra
Publicado em: (2023)
article Enhanced ectasia detection using corneal tomography and biomechanics
por: Mendes, José Ferreira
Publicado em: (2019)
por: Mendes, José Ferreira
Publicado em: (2019)
article The influence of the tear film on the intraocular pressure and the corneal biomechanical properties analyzed with the Ocular Response Analyzer
por: Silva, Filipe da
Publicado em: (2024)
por: Silva, Filipe da
Publicado em: (2024)
article Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
por: Macedo-de-Araújo, Rute J.
Publicado em: (2023)
por: Macedo-de-Araújo, Rute J.
Publicado em: (2023)
article Biocompatibility evaluation of bacterial cellulose as a scaffold material for tissue-engineered corneal stroma
por: Zhang, Chen
Publicado em: (2020)
por: Zhang, Chen
Publicado em: (2020)
school Edema corneal com lentes esclerais
por: Oliveira, Cristina Daniela Moreira
Publicado em: (2013)
por: Oliveira, Cristina Daniela Moreira
Publicado em: (2013)
article End-of-day dryness, corneal sensitivity and blink rate in contact lens wearers
por: Martín-Montañez, Vicente
Publicado em: (2015)
por: Martín-Montañez, Vicente
Publicado em: (2015)
article Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
por: González-Méijome, José Manuel
Publicado em: (2003)
por: González-Méijome, José Manuel
Publicado em: (2003)
school Lamellar keratoplasty for the treatment of feline corneal sequestrum
por: Gonçalves, Catarina Alexandra Ventura
Publicado em: (2015)
por: Gonçalves, Catarina Alexandra Ventura
Publicado em: (2015)
article Local steepening in peripheral corneal curvature after corneal refractive therapy and LASIK
por: Queirós, A.
Publicado em: (2010)
por: Queirós, A.
Publicado em: (2010)
image Análisis de las aberraciones para diferentes diámetros pupilares en usuarios de ortoqueratología nocturna
por: Santolaria Sanz, Elena
Publicado em: (2012)
por: Santolaria Sanz, Elena
Publicado em: (2012)
article The thinnest, steepest, and maximum elevation Corneal locations in noncontact and contact lens wearers in keratoconus
por: Romero-Jimenez, Miguel
Publicado em: (2013)
por: Romero-Jimenez, Miguel
Publicado em: (2013)
article Ocular and corneal aberrations changes in controlled randomized clinical trial MiSight® Assessment Study Spain (MASS)
por: Lopes-Ferreira, Daniela
Publicado em: (2021)
por: Lopes-Ferreira, Daniela
Publicado em: (2021)
article Clinical intelligence: A study on corneal transplantation
por: Carneiro, Brian
Publicado em: (2017)
por: Carneiro, Brian
Publicado em: (2017)
article Modeling ophthalmic surfaces using Zernike, Bessel and Chebyshev type functions
por: Rodrigues, Maria Manuela Fernandes
Publicado em: (2019)
por: Rodrigues, Maria Manuela Fernandes
Publicado em: (2019)
article Stabilization in early adult-onset myopia with corneal refractive therapy
por: González-Méijome, José Manuel
Publicado em: (2016)
por: González-Méijome, José Manuel
Publicado em: (2016)
article Corneal sub-basal nerve plexus assessment and its association with phenotypic features and lymphocyte subsets in Sjögren's Syndrome
por: Barcelos, Filipe
Publicado em: (2021)
por: Barcelos, Filipe
Publicado em: (2021)
Registos relacionados
-
article Multi-aspheric description of the myopic cornea after different refractive treatments and its correlation with corneal higher order aberrations
por: Queirós, A.
Publicado em: (2012) -
image Topographical changes in anterior corneal curvature after LASIK
por: González-Méijome, José Manuel
Publicado em: (2004) -
category Within and between session repeatability of topographic data using medmont E-300 corneal topographer
por: Fernandes, Paulo Rodrigues
Publicado em: (2005) -
article New method for measuring thickness in thin transparent medium
por: Sousa, Raul A. R. C.
Publicado em: (2011) -
article A pilot study on the influence of biomechanical properties of the cornea on short-term response to myopic corneal refractive therapy
por: González-Méijome, José Manuel
Publicado em: (2008)