Publicação
Prototype for determination of pre-transfusion tests based on image processing techniques
| Resumo: | This paper presents an innovative prototype to perform pre-transfusion tests especially developed for emergency situations. This prototype is portable and automates the procedure of the plate test. The prototype is based on image processing techniques to analyze the captured images from the performed test. The image processing techniques are able to detect agglutination reactions in the samples and based on the results of occurrence or absence of agglutination the result of the test is given. This paper also presents a user-friendly interface application to be used with the prototype developed. In this study the tests were performed with the prototype for ABO and Rh blood types and the prototype was tested with donor blood samples. |
|---|---|
| Autores principais: | Ferraz, Ana |
| Outros Autores: | Machado, José; Carvalho, Vitor |
| Assunto: | prototype blood type pre-transfusion tests image processing |
| Ano: | 2015 |
| País: | Portugal |
| Tipo de documento: | comunicação em conferência |
| Tipo de acesso: | acesso restrito |
| Instituição associada: | Universidade do Minho |
| Idioma: | inglês |
| Origem: | RepositóriUM - Universidade do Minho |
| _version_ | 1866878107732934656 |
|---|---|
| author | Ferraz, Ana |
| author2 | Machado, José Carvalho, Vitor |
| author2_role | author author |
| author_facet | Ferraz, Ana Machado, José Carvalho, Vitor |
| author_role | author |
| contributor_name_str_mv | Universidade do Minho |
| country_str | PT |
| creators_json_txt | [{\"Person.name\":\"Ferraz, Ana\"},{\"Person.name\":\"Machado, José\"},{\"Person.name\":\"Carvalho, Vitor\"}] |
| datacite.contributors.contributor.contributorName.fl_str_mv | Universidade do Minho |
| datacite.creators.creator.creatorName.fl_str_mv | Ferraz, Ana Machado, José Carvalho, Vitor |
| datacite.date.Accepted.fl_str_mv | 2015-01-01T00:00:00Z |
| datacite.rights.fl_str_mv | http://purl.org/coar/access_right/c_16ec |
| datacite.subjects.subject.fl_str_mv | prototype blood type pre-transfusion tests image processing |
| datacite.titles.title.fl_str_mv | Prototype for determination of pre-transfusion tests based on image processing techniques |
| dc.contributor.none.fl_str_mv | Universidade do Minho |
| dc.creator.none.fl_str_mv | Ferraz, Ana Machado, José Carvalho, Vitor |
| dc.date.Accepted.fl_str_mv | 2015-01-01T00:00:00Z |
| dc.format.none.fl_str_mv | application/pdf |
| dc.identifier.none.fl_str_mv | https://hdl.handle.net/1822/53614 |
| dc.language.none.fl_str_mv | eng |
| dc.publisher.none.fl_str_mv | IEEE |
| dc.rights.none.fl_str_mv | http://purl.org/coar/access_right/c_16ec |
| dc.subject.none.fl_str_mv | prototype blood type pre-transfusion tests image processing |
| dc.title.fl_str_mv | Prototype for determination of pre-transfusion tests based on image processing techniques |
| dc.type.none.fl_str_mv | http://purl.org/coar/resource_type/c_5794 |
| description | This paper presents an innovative prototype to perform pre-transfusion tests especially developed for emergency situations. This prototype is portable and automates the procedure of the plate test. The prototype is based on image processing techniques to analyze the captured images from the performed test. The image processing techniques are able to detect agglutination reactions in the samples and based on the results of occurrence or absence of agglutination the result of the test is given. This paper also presents a user-friendly interface application to be used with the prototype developed. In this study the tests were performed with the prototype for ABO and Rh blood types and the prototype was tested with donor blood samples. |
| dirty | 0 |
| eu_rights_str_mv | restrictedAccess |
| format | conferencePaper |
| fulltext.url.fl_str_mv | https://prod-dspace.uminho.pt/bitstreams/fb875da7-f1ce-49c5-8471-65179f1ac223/download |
| id | rum_e855fbfc8c461efa05b5c4a0bcfeeb41 |
| identifier.url.fl_str_mv | https://hdl.handle.net/1822/53614 |
| instacron_str | repositorium |
| institution | Universidade do Minho |
| instname_str | Universidade do Minho |
| language | eng |
| network_acronym_str | rum |
| network_name_str | RepositóriUM - Universidade do Minho |
| oai_identifier_str | oai:repositorium.uminho.pt:1822/53614 |
| organization_str_mv | urn:organizationAcronym:repositorium |
| person_str_mv | Ferraz, Ana Machado, José Carvalho, Vitor |
| publishDate | 2015 |
| publisher.none.fl_str_mv | IEEE |
| reponame_str | RepositóriUM - Universidade do Minho |
| repository_id_str | urn:repositoryAcronym:rum |
| service_str_mv | urn:repositoryAcronym:rum |
| spelling | engIEEEporThis paper presents an innovative prototype to perform pre-transfusion tests especially developed for emergency situations. This prototype is portable and automates the procedure of the plate test. The prototype is based on image processing techniques to analyze the captured images from the performed test. The image processing techniques are able to detect agglutination reactions in the samples and based on the results of occurrence or absence of agglutination the result of the test is given. This paper also presents a user-friendly interface application to be used with the prototype developed. In this study the tests were performed with the prototype for ABO and Rh blood types and the prototype was tested with donor blood samples.application/pdfporPrototype for determination of pre-transfusion tests based on image processing techniquesFerraz, AnaMachado, JoséCarvalho, VitorHostingInstitutionOrganizationalUniversidade do Minhoe-mailmailto:repositorium@usdb.uminho.ptrepositorium@usdb.uminho.ptISBNIsPartOf9781479982691DOIIsPartOf10.1109/ENBENG.2015.708884920152018-03-24T10:52:02Z2015-01-01T00:00:00ZHandlehttps://hdl.handle.net/1822/53614http://purl.org/coar/access_right/c_16ecrestricted accessprototypeblood typepre-transfusion testsimage processing529354 bytesother research producthttp://purl.org/coar/resource_type/c_5794conference paperhttp://purl.org/coar/access_right/c_16ecapplication/pdffulltexthttps://prod-dspace.uminho.pt/bitstreams/fb875da7-f1ce-49c5-8471-65179f1ac223/download |
| spellingShingle | Prototype for determination of pre-transfusion tests based on image processing techniques Ferraz, Ana prototype blood type pre-transfusion tests image processing |
| status | SINGLETON |
| subject.fl_str_mv | prototype blood type pre-transfusion tests image processing |
| title | Prototype for determination of pre-transfusion tests based on image processing techniques |
| title_full | Prototype for determination of pre-transfusion tests based on image processing techniques |
| title_fullStr | Prototype for determination of pre-transfusion tests based on image processing techniques |
| title_full_unstemmed | Prototype for determination of pre-transfusion tests based on image processing techniques |
| title_short | Prototype for determination of pre-transfusion tests based on image processing techniques |
| title_sort | Prototype for determination of pre-transfusion tests based on image processing techniques |
| topic | prototype blood type pre-transfusion tests image processing |
| topic_facet | prototype blood type pre-transfusion tests image processing |
| url | https://hdl.handle.net/1822/53614 |
| visible | 1 |