Resumo:Nowadays, and regardless of the activity sector, ensuring product quality and customer satisfaction is the main focus of organizations. In this sense, and since measuring and monitoring equipment (MME) are essentially used in product conformity assessment, an efficient management of the calibration process of these instruments becomes crucial for organizational performance. Although there are several methods for defining calibration intervals, there is a lack of guidelines for selecting the most appropriate method for each situation. Therefore, this paper has as its main goal to present an approach to assist in the management of calibration intervals for MME. This approach is intended to identify, considering a set of factors associated with the characteristics of the measuring instrument and its condition and use environment, which method for setting calibration intervals has the greatest potential for each case. A case study was performed, using data from a set of measuring instruments of an organization that produces cork stoppers, which allowed conclusions to be drawn for each method under study. In the end, with the development and application of the approach, it was concluded that an appropriate choice of the method for defining calibration intervals allows a more efficient management of the measuring and monitoring equipment, in terms of aptitude and adequacy of its metrological capacity within the productive sector.
Autores principais:Sousa, Ana Margarida Ferreira
Outros Autores:Lopes, Isabel da Silva; Pires, Cláudia; Mendonca, Joao Pedro
Assunto:Calibration Methods for defining calibration intervals Optimal Calibration Intervals
Ano:2024
País:Portugal
Tipo de documento:comunicação em conferência
Tipo de acesso:acesso restrito
Instituição associada:Universidade do Minho
Idioma:inglês
Origem:RepositóriUM - Universidade do Minho
_version_ 1867439182988705792
author Sousa, Ana Margarida Ferreira
author2 Lopes, Isabel da Silva
Pires, Cláudia
Mendonca, Joao Pedro
author2_role author
author
author
author_facet Sousa, Ana Margarida Ferreira
Lopes, Isabel da Silva
Pires, Cláudia
Mendonca, Joao Pedro
author_role author
contributor_name_str_mv RepositóriUM - Universidade do Minho
country_str PT
creators_json_txt [{\"Person.name\":\"Sousa, Ana Margarida Ferreira\"},{\"Person.name\":\"Lopes, Isabel da Silva\"},{\"Person.name\":\"Pires, Cláudia\"},{\"Person.name\":\"Mendonca, Joao Pedro\"}]
datacite.contributors.contributor.contributorName.fl_str_mv RepositóriUM - Universidade do Minho
datacite.creators.creator.creatorName.fl_str_mv Sousa, Ana Margarida Ferreira
Lopes, Isabel da Silva
Pires, Cláudia
Mendonca, Joao Pedro
datacite.date.Accepted.fl_str_mv 2024-01-01T00:00:00Z
datacite.date.embargoed.fl_str_mv 10000-01-01T00:00:00Z
datacite.rights.fl_str_mv http://purl.org/coar/access_right/c_16ec
datacite.subjects.subject.fl_str_mv Calibration
Methods for defining calibration intervals
Optimal Calibration Intervals
datacite.titles.title.fl_str_mv Selecting the method for setting the calibration intervals of metrological devices
dc.contributor.none.fl_str_mv RepositóriUM - Universidade do Minho
dc.creator.none.fl_str_mv Sousa, Ana Margarida Ferreira
Lopes, Isabel da Silva
Pires, Cláudia
Mendonca, Joao Pedro
dc.date.Accepted.fl_str_mv 2024-01-01T00:00:00Z
dc.date.embargoed.fl_str_mv 10000-01-01T00:00:00Z
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv https://hdl.handle.net/1822/96051
dc.language.none.fl_str_mv eng
dc.publisher.none.fl_str_mv Springer Nature
dc.rights.none.fl_str_mv http://purl.org/coar/access_right/c_16ec
dc.subject.none.fl_str_mv Calibration
Methods for defining calibration intervals
Optimal Calibration Intervals
dc.title.fl_str_mv Selecting the method for setting the calibration intervals of metrological devices
dc.type.none.fl_str_mv http://purl.org/coar/resource_type/c_5794
description Nowadays, and regardless of the activity sector, ensuring product quality and customer satisfaction is the main focus of organizations. In this sense, and since measuring and monitoring equipment (MME) are essentially used in product conformity assessment, an efficient management of the calibration process of these instruments becomes crucial for organizational performance. Although there are several methods for defining calibration intervals, there is a lack of guidelines for selecting the most appropriate method for each situation. Therefore, this paper has as its main goal to present an approach to assist in the management of calibration intervals for MME. This approach is intended to identify, considering a set of factors associated with the characteristics of the measuring instrument and its condition and use environment, which method for setting calibration intervals has the greatest potential for each case. A case study was performed, using data from a set of measuring instruments of an organization that produces cork stoppers, which allowed conclusions to be drawn for each method under study. In the end, with the development and application of the approach, it was concluded that an appropriate choice of the method for defining calibration intervals allows a more efficient management of the measuring and monitoring equipment, in terms of aptitude and adequacy of its metrological capacity within the productive sector.
dirty 0
eu_rights_str_mv restrictedAccess
format conferencePaper
fulltext.url.fl_str_mv https://repositorium.uminho.pt/bitstreams/398e17eb-4206-4a62-a311-beaab4130eac/download
id rum_fcbc81449c3db00a2cb1a5c8d6ec2077
identifier.url.fl_str_mv https://hdl.handle.net/1822/96051
instacron_str repositorium
institution Universidade do Minho
instname_str Universidade do Minho
language eng
network_acronym_str rum
network_name_str RepositóriUM - Universidade do Minho
oai_identifier_str oai:repositorium.uminho.pt:1822/96051
organization_str_mv urn:organizationAcronym:repositorium
person_str_mv Sousa, Ana Margarida Ferreira
Lopes, Isabel da Silva
Pires, Cláudia
Mendonca, Joao Pedro
publishDate 2024
publisher.none.fl_str_mv Springer Nature
reponame_str RepositóriUM - Universidade do Minho
repository_id_str urn:repositoryAcronym:rum
service_str_mv urn:repositoryAcronym:rum
spelling engSpringer NatureporNowadays, and regardless of the activity sector, ensuring product quality and customer satisfaction is the main focus of organizations. In this sense, and since measuring and monitoring equipment (MME) are essentially used in product conformity assessment, an efficient management of the calibration process of these instruments becomes crucial for organizational performance. Although there are several methods for defining calibration intervals, there is a lack of guidelines for selecting the most appropriate method for each situation. Therefore, this paper has as its main goal to present an approach to assist in the management of calibration intervals for MME. This approach is intended to identify, considering a set of factors associated with the characteristics of the measuring instrument and its condition and use environment, which method for setting calibration intervals has the greatest potential for each case. A case study was performed, using data from a set of measuring instruments of an organization that produces cork stoppers, which allowed conclusions to be drawn for each method under study. In the end, with the development and application of the approach, it was concluded that an appropriate choice of the method for defining calibration intervals allows a more efficient management of the measuring and monitoring equipment, in terms of aptitude and adequacy of its metrological capacity within the productive sector.application/pdfporSelecting the method for setting the calibration intervals of metrological devicesSousa, Ana Margarida FerreiraLopes, Isabel da SilvaPires, CláudiaMendonca, Joao PedroHostingInstitutionOrganizationalRepositóriUM - Universidade do Minhoe-mailmailto:repositorium@usdb.uminho.ptrepositorium@usdb.uminho.ptISBNIsPartOf978-3-031-38164-5ISSNIsPartOf2195-4356EISSNIsPartOf2195-4364DOIIsPartOf10.1007/978-3-031-38165-2_10EISBNIsPartOf978-3-031-38165-220242025-06-02T07:58:18Z10000-01-01T00:00:00Z2024-01-01T00:00:00ZHandlehttps://hdl.handle.net/1822/96051http://purl.org/coar/access_right/c_16ecrestricted accessCalibrationMethods for defining calibration intervalsOptimal Calibration Intervals412075 bytesother research producthttp://purl.org/coar/resource_type/c_5794conference paperhttp://purl.org/coar/access_right/c_f1cfapplication/pdffulltexthttps://repositorium.uminho.pt/bitstreams/398e17eb-4206-4a62-a311-beaab4130eac/download
spellingShingle Selecting the method for setting the calibration intervals of metrological devices
Sousa, Ana Margarida Ferreira
Calibration
Methods for defining calibration intervals
Optimal Calibration Intervals
status SINGLETON
subject.fl_str_mv Calibration
Methods for defining calibration intervals
Optimal Calibration Intervals
title Selecting the method for setting the calibration intervals of metrological devices
title_full Selecting the method for setting the calibration intervals of metrological devices
title_fullStr Selecting the method for setting the calibration intervals of metrological devices
title_full_unstemmed Selecting the method for setting the calibration intervals of metrological devices
title_short Selecting the method for setting the calibration intervals of metrological devices
title_sort Selecting the method for setting the calibration intervals of metrological devices
topic Calibration
Methods for defining calibration intervals
Optimal Calibration Intervals
topic_facet Calibration
Methods for defining calibration intervals
Optimal Calibration Intervals
url https://hdl.handle.net/1822/96051
visible 1