Publicação
Bone remodelling of the humerus after a resurfacing and a stemless shoulder arthroplasty
| Resumo: | Background: New implant designs, such as resurfacing and stemless implants, have been developed to improve the long-term outcomes of the shoulder arthroplasty. However, it is not yet fully understood if their influence on the bone load distribution can compromise the long-term stability of the implant due to bone mass changes. Using three-dimensional finite element models, the aim of the present study was to analyse the bone remodelling process of the humerus after the introduction of resurfacing and stemless implants based on the Global C.A.P. and Sidus Stem-Free designs, respectively. Methods: The 3D geometric model of the humerus was generated from the CT data of the Visible Human Project and the resurfacing and stemless implants were modelled in Solidworks. Considering a native humerus model, a humerus model with the resurfacing implant, and a humerus model with the stemless implant, three finite element models were developed in Abaqus. Bone remodelling simulations were performed considering healthy and poor bone quality conditions. The loading condition considered comprised 6 load cases of standard shoulder movements, including muscle and joint reaction forces estimated by a multibody model of the upper limb. Findings: The results showed similar levels of bone resorption for the resurfacing and stemless implants for common humeral regions. The regions underneath the head of the resurfacing implant, unique to this design, showed the largest bone loss. For both implants, bone resorption was more pronounced for the poor bone quality condition than for the healthy bone quality condition. Interpretation: The stemless implant lost less density at the fixation site, which might suggest that these implants may be better supported in the long-term than the resurfacing implants. However, further investigation is necessary to allow definite recommendations. |
|---|---|
| Autores principais: | Santos, B. |
| Outros Autores: | Quental, Carlos; Folgado, João; Sarmento, Marco; Monteiro, Jacinto |
| Assunto: | Bone remodelling Finite element method Resurfacing implant Shoulder arthroplasty Shoulder joint Stemless implant |
| Ano: | 2018 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso restrito |
| Instituição associada: | Universidade de Lisboa |
| Idioma: | inglês |
| Origem: | Repositório da Universidade de Lisboa |
Registos relacionados
article Primary stability analysis of stemless shoulder implants
por: Quental, C.
Publicado em: (2020)
por: Quental, C.
Publicado em: (2020)
article Finite element model validation based on an experimental model of the intact shoulder joint
por: Bola, Margarida
Publicado em: (2021)
por: Bola, Margarida
Publicado em: (2021)
article The pectoralis minor muscle and shoulder movement-related impairments and pain: Rationale, assessment and management
por: Morais, Nuno
Publicado em: (2016)
por: Morais, Nuno
Publicado em: (2016)
article Sistema de fabrico rápido de implantes ortopédicos
por: Relvas, Carlos
Publicado em: (2009)
por: Relvas, Carlos
Publicado em: (2009)
article Ulnar Head Arthroplasty with Posterior Interosseous Nerve Neurectomy: A Case Report
por: Mata Ribeiro, L
Publicado em: (2018)
por: Mata Ribeiro, L
Publicado em: (2018)
article Electromyographic activity of shoulder muscles on two preventive exercise programmes for swimmer’s shoulder: elastic band versus weight
por: Tavares, Nuno
Publicado em: (2025)
por: Tavares, Nuno
Publicado em: (2025)
text_fields Shoulder Septic Arthritis in the Pediatric Age - an Epidemiologic Study
por: Brazão, Carla
Publicado em: (2024)
por: Brazão, Carla
Publicado em: (2024)
book The computational mechanics of bone tissue: biologic behaviour, remodelling algorithms and numerical applications
por: Belinha, J
Publicado em: (2020)
por: Belinha, J
Publicado em: (2020)
article The influence of condylar geometry and positions of bone fixation screws on a TMJ implant
por: Ramos, A.
Publicado em: (2010)
por: Ramos, A.
Publicado em: (2010)
article The acute effects of a swimming session on the shoulder rotators strength and balance of age group swimmers
por: Batalha, Nuno
Publicado em: (2021)
por: Batalha, Nuno
Publicado em: (2021)
article Ultrasound findings and prognosis of shoulder pain: a role for Doppler signal?
por: Janeiro, João
Publicado em: (2023)
por: Janeiro, João
Publicado em: (2023)
groups The influence of stem design on strains and micromotion in revision Total Knee Arthroplasty: Finite element analysis
por: Completo, António
Publicado em: (2006)
por: Completo, António
Publicado em: (2006)
groups Biomechanical response of new femoral components for patellofemoral arthroplasty
por: Castro, André
Publicado em: (2011)
por: Castro, André
Publicado em: (2011)
article Effect of shoulder cavity and welding parameters on friction stir welding of thin copper sheets
por: Leal, R. M.
Publicado em: (2011)
por: Leal, R. M.
Publicado em: (2011)
article Influence of tool shoulder geometry on properties of friction stir welds in thin copper sheets
por: Galvão, I.
Publicado em: (2013)
por: Galvão, I.
Publicado em: (2013)
article Kinematic Comparison and Description of the 3-Dimensional Shoulder Kinematics of 2 Shoulder Rotation Tests
por: Pascoal, Augusto Gil
Publicado em: (2015)
por: Pascoal, Augusto Gil
Publicado em: (2015)
description A novel computational modelling to describe the anisotropic, remodelling and reorientation behaviour of collagen fibres in articular cartilage
por: Cortez, Sara
Publicado em: (2016)
por: Cortez, Sara
Publicado em: (2016)
groups Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
por: São João, Ricardo
Publicado em: (2019)
por: São João, Ricardo
Publicado em: (2019)
school Development of a prototype for sensing bone-implant interface
por: Peres, Inês Simões
Publicado em: (2020)
por: Peres, Inês Simões
Publicado em: (2020)
article Straight, semi-anatomic and anatomic TMJ implants: the influence of condylar geometry and bone fixation screws
por: Ramos, A.
Publicado em: (2011)
por: Ramos, A.
Publicado em: (2011)
school Performance of a capacitive monitoring system for instrumented bone implants
por: Cachão, João Henrique Gamito Trindade Carvalho
Publicado em: (2019)
por: Cachão, João Henrique Gamito Trindade Carvalho
Publicado em: (2019)
school Mechanical strength study of cranial implants
por: Santos, Pedro Oliveira
Publicado em: (2021)
por: Santos, Pedro Oliveira
Publicado em: (2021)
article Cross-cultural Adaptation and Validation of the European Portuguese Version of the Western Ontario Shoulder Instability Index (WOSI)
por: Torres, Rui Manuel
Publicado em: (2022)
por: Torres, Rui Manuel
Publicado em: (2022)
article Dynamic modeling of bone remodeling, osteolytic metastasis and PK/PD therapy: introducing variable order derivatives as a simplification technique
por: Neto, Joana Pinheiro
Publicado em: (2021)
por: Neto, Joana Pinheiro
Publicado em: (2021)
article Biomechanical evaluation of pyrocarbon proximal interphalangeal joint arthroplasty: An in-vitro analysis
por: Completo, António
Publicado em: (2018)
por: Completo, António
Publicado em: (2018)
article Pre-clinical test to discriminate shoulder performance
por: Bola, Ana Margarida
Publicado em: (2019)
por: Bola, Ana Margarida
Publicado em: (2019)
school Validação e otimização de conceito prótese resurfacing da anca em Si3N4
por: Oliveira, Mariana Ribeiro de
Publicado em: (2021)
por: Oliveira, Mariana Ribeiro de
Publicado em: (2021)
article Effect of Preventive Exercise Programs for Swimmer’s Shoulder Injury on Rotator Cuff Torque and Balance in Competitive Swimmers: A Randomized Controlled Trial
por: Tavares, Nuno
Publicado em: (2025)
por: Tavares, Nuno
Publicado em: (2025)
article Experimental bone strain analysis in distal tip of tibial stems in revision Total Knee Arthroplasty
por: Completo, António
Publicado em: (2008)
por: Completo, António
Publicado em: (2008)
article Revision total knee arthroplasty: the influence of femoral stems in load sharing and stability
por: Completo, A.
Publicado em: (2009)
por: Completo, A.
Publicado em: (2009)
article The kinematic chain of arm elevation is impaired in patients with chronic obstructive pulmonary disease
por: Morais, Nuno
Publicado em: (2019)
por: Morais, Nuno
Publicado em: (2019)
article Femoral revision knee Arthroplasty with Metaphyseal sleeves: the use of a stem is not mandatory of a structural point of view
por: Fonseca, F.
Publicado em: (2020)
por: Fonseca, F.
Publicado em: (2020)
article Peri-Prosthetic Bone Cysts After Total Ankle Replacement. A Systematic Review and Meta-Analysis
por: Arcângelo, J
Publicado em: (2019)
por: Arcângelo, J
Publicado em: (2019)
article Total arthroplasty of basal thumb joint with Elektra prosthesis: An in vitro analysis
por: Completo, António
Publicado em: (2016)
por: Completo, António
Publicado em: (2016)
school Development of the Stationary Shoulder Friction Stir Channelling process on Die Cast Aluminium Alloy 383 for Thermal Management Applications
por: Mendes, Rita Isabel Soares
Publicado em: (2024)
por: Mendes, Rita Isabel Soares
Publicado em: (2024)
article Mathematical Models for Prediction of Temperature Effects on Kinetic Parameters of Microorganisms’ Inactivation: Tools for Model Comparison and Adequacy in Data Fitting
por: Gil, Maria M
Publicado em: (2017)
por: Gil, Maria M
Publicado em: (2017)
article Bone density and proximal support effects on dental implant stability - finite element analysis and in vitro experiments
por: Gomes, C.
Publicado em: (2023)
por: Gomes, C.
Publicado em: (2023)
groups Biomechanical investigations on the total knee arthroplasty
por: Fonseca, F.
Publicado em: (2006)
por: Fonseca, F.
Publicado em: (2006)
article Biomechanical analysis of metacarpophalangeal joint arthroplasty with metal-polyethylene implant: An in-vitro study
por: Melo, D
Publicado em: (2019)
por: Melo, D
Publicado em: (2019)
school Combating shoulder-surfing: a hidden button gesture based scheme
por: Rodrigues, Mário Amilcar Freitas
Publicado em: (2009)
por: Rodrigues, Mário Amilcar Freitas
Publicado em: (2009)
Registos relacionados
-
article Primary stability analysis of stemless shoulder implants
por: Quental, C.
Publicado em: (2020) -
article Finite element model validation based on an experimental model of the intact shoulder joint
por: Bola, Margarida
Publicado em: (2021) -
article The pectoralis minor muscle and shoulder movement-related impairments and pain: Rationale, assessment and management
por: Morais, Nuno
Publicado em: (2016) -
article Sistema de fabrico rápido de implantes ortopédicos
por: Relvas, Carlos
Publicado em: (2009) -
article Ulnar Head Arthroplasty with Posterior Interosseous Nerve Neurectomy: A Case Report
por: Mata Ribeiro, L
Publicado em: (2018)