Resumo:The thermal loading of an open car park building structure is going to be analysed, based on different fire scenarios that depend on the type of vehicle (different heat release rate). The compartment is going to be fixed and the thermal effect on beams is going to be analysed, depending on the vehicle position. The result of simple calculation method will be used to determine several temperature-time curves. The simple calculation method (Hasemi method) is also to be compared with the calculations of the Elefir-EN calculation program to analyse the thermal effect of the localized fire on beams.
Autores principais:Fettah, Bilal
Assunto:Localized fire Open car park Steel structure Elefir-EN Correlative model Incêndio localizado,
Ano:2016
País:Portugal
Tipo de documento:dissertação de mestrado
Tipo de acesso:acesso aberto
Instituição associada:Instituto Politécnico de Bragança
Idioma:inglês
Origem:Biblioteca Digital do IPB
Descrição
Resumo:The thermal loading of an open car park building structure is going to be analysed, based on different fire scenarios that depend on the type of vehicle (different heat release rate). The compartment is going to be fixed and the thermal effect on beams is going to be analysed, depending on the vehicle position. The result of simple calculation method will be used to determine several temperature-time curves. The simple calculation method (Hasemi method) is also to be compared with the calculations of the Elefir-EN calculation program to analyse the thermal effect of the localized fire on beams.