Resumo:Columns packed with commercial glass beads of 5 and 19 microns average diameter and binary mixtures with finest fraction of 5 micron (30 % volume fraction of the mixture) were used to analyse starch by hydrodynamic chromatography (HDC). Experiments were carried out at 3 and 15 ºC. The observed resolution increased with the application of binary packing as compared with single-size packing. The best results were obtained at starch’s amylopectin and amylose separation with a glass beads mixture (5 + 19 micron) at 3ºC. In what concerns amylopectin and amylose separation, a lower pressure drop were obtained for the mixed binary packing when compared with the packing containing uniform 5 micron glass beads. For the Hylon VII starch RRT were 0.777 and 0.964 for amylopectin (AP) and amylose (AM), respectively, while for the Tapioca starch the obtained RRTs were 0.799 and 0.923. Application of unbound glass beads as column packing might reduce equipment and running costs in preparative scale separations.
Autores principais:Mota, Manuel
Outros Autores:Teixeira, José; Dias, Ricardo P.; Yelshin, Alexander
Assunto:Starch Hydrodynamic chromatography Macromolecules
Ano:2008
País:Portugal
Tipo de documento:comunicação em conferência
Tipo de acesso:acesso aberto
Instituição associada:Instituto Politécnico de Bragança
Idioma:inglês
Origem:Biblioteca Digital do IPB
Descrição
Resumo:Columns packed with commercial glass beads of 5 and 19 microns average diameter and binary mixtures with finest fraction of 5 micron (30 % volume fraction of the mixture) were used to analyse starch by hydrodynamic chromatography (HDC). Experiments were carried out at 3 and 15 ºC. The observed resolution increased with the application of binary packing as compared with single-size packing. The best results were obtained at starch’s amylopectin and amylose separation with a glass beads mixture (5 + 19 micron) at 3ºC. In what concerns amylopectin and amylose separation, a lower pressure drop were obtained for the mixed binary packing when compared with the packing containing uniform 5 micron glass beads. For the Hylon VII starch RRT were 0.777 and 0.964 for amylopectin (AP) and amylose (AM), respectively, while for the Tapioca starch the obtained RRTs were 0.799 and 0.923. Application of unbound glass beads as column packing might reduce equipment and running costs in preparative scale separations.