Métrica vertebral: a aplicação de uma nova tecnologia na análise da coluna vertebral

Ver documento

Detalhes bibliográficos
Resumo:Objective: To present the results of the first application of the new technology - Vertebral Metrics - the analysis of the 3D position of the vertex of each spinous process in pregnant women. Material and Methods: The Vertebral Metrics was applied to women without associated pathology in four stages of pregnancy (12, 20, 32, 37 weeks gestation). We applied univariate linear models. Results: We found that the differences that occur during pregnancy are more significant at the position y (anteroposterior). It was found also that there is a positive correlation between the biomechanical position of the vertex of each of the vertebrae with the homologous position of rest. Discussion/Conclusion: Through Vertebral Metrics innovative results could be obtained in analyzing biomechanics of the spine. A device that has different applications can be easily adopted in areas such as orthopedics, neurosurgery, pediatrics and rehabilitation. It should also be noted that this instrument is not exhausted in the sample of this research because it can be further applied to the general population.
Autores principais:Quaresma, Cláudia
Outros Autores:Dias, I.; Forjaz Secca, M.; Goyri-O'neill, J.; Branco, J.
Assunto:Biomechanics Equipment design Imaging Posture Pregnancy Spine Three-dimensional Body position Body posture Metric system Vertebra body Female Biomecânica Desenho de Equipamento Postura Coluna vertebral imagem tridimensional Gravidez
Ano:2013
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Instituto Politécnico de Beja
Idioma:português
Origem:Repositório Institucional do IPBeja
Descrição
Resumo:Objective: To present the results of the first application of the new technology - Vertebral Metrics - the analysis of the 3D position of the vertex of each spinous process in pregnant women. Material and Methods: The Vertebral Metrics was applied to women without associated pathology in four stages of pregnancy (12, 20, 32, 37 weeks gestation). We applied univariate linear models. Results: We found that the differences that occur during pregnancy are more significant at the position y (anteroposterior). It was found also that there is a positive correlation between the biomechanical position of the vertex of each of the vertebrae with the homologous position of rest. Discussion/Conclusion: Through Vertebral Metrics innovative results could be obtained in analyzing biomechanics of the spine. A device that has different applications can be easily adopted in areas such as orthopedics, neurosurgery, pediatrics and rehabilitation. It should also be noted that this instrument is not exhausted in the sample of this research because it can be further applied to the general population.