Publicação

IL-5 serum and appendicular lavage fluid concentrations correlate with eosinophilic infiltration in the appendicular wall supporting a role for a hypersensitivity type I reaction in acute appendicitis

Ver documento

Detalhes bibliográficos
Resumo:Appendicitis is the most common abdominal surgical emergency, but its aetiology is not fully understood. We and others have proposed that allergic responses play significant roles in its pathophysiology. Eosinophils and Interleukin (IL)-5 are involved in a hypersensitivity type I reaction. Eosinophil infiltration is common in the allergic target organ and is dependent on IL-5. In the presence of an allergic component, it is expected that the eosinophil count and IL-5 local and systemic concentrations become elevated. To address this hypothesis, we designed a prospective study that included 65 patients with acute appendicitis (grouped as acute phlegmonous or gangrenous according to the histological definition) and 18 patients with the clinical diagnosis of acute appendicitis, but with normal histological findings (control group) were enrolled. Eosinophil blood counts and appendicular wall eosinophil infiltration were determined. IL-5 levels in the blood and appendicular lavage fluid were evaluated. Appendicular lavage fluid was collected by a new methodology developed and standardized by our group. Appendicular wall eosinophil infiltration was higher in acute phlegmonous appendicitis than in gangrenous appendicitis (p = 0.000). IL-5 blood levels were similar in both pathologic and control groups (p > 0.05). In the appendicular lavage fluid, higher levels of IL-5 were observed in the phlegmonous appendicitis group (p = 0.056). We found a positive correlation between the appendicular wall eosinophilic infiltration and the IL-5 concentrations, in both the blood and the appendicular lavage fluid, supporting the IL-5 reliance in eosinophil local infiltration. We observed the highest presence of eosinophils at phlegmonous appendicitis walls. In conclusion, the present data are compatible with a hypersensitivity type I allergic reaction in the target organ, the appendix, during the phlegmonous phase of appendicitis.
Autores principais:Carvalho, Nuno
Outros Autores:Carolino, Elisabete; Coelho, Hélder; Cóias, Ana; Trindade, Madalena; Vaz, João; Cismasiu, Brigitta; Moita, Catarina; Moita, Luis; Costa, Paulo Matos
Assunto:Allergy Appendicitis Appendicular lavage fluid Eosinophils IL-5 Th2 cytokine
Ano:2022
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Instituto Politécnico de Lisboa
Idioma:inglês
Origem:Repositório Científico do Instituto Politécnico de Lisboa
Descrição
Resumo:Appendicitis is the most common abdominal surgical emergency, but its aetiology is not fully understood. We and others have proposed that allergic responses play significant roles in its pathophysiology. Eosinophils and Interleukin (IL)-5 are involved in a hypersensitivity type I reaction. Eosinophil infiltration is common in the allergic target organ and is dependent on IL-5. In the presence of an allergic component, it is expected that the eosinophil count and IL-5 local and systemic concentrations become elevated. To address this hypothesis, we designed a prospective study that included 65 patients with acute appendicitis (grouped as acute phlegmonous or gangrenous according to the histological definition) and 18 patients with the clinical diagnosis of acute appendicitis, but with normal histological findings (control group) were enrolled. Eosinophil blood counts and appendicular wall eosinophil infiltration were determined. IL-5 levels in the blood and appendicular lavage fluid were evaluated. Appendicular lavage fluid was collected by a new methodology developed and standardized by our group. Appendicular wall eosinophil infiltration was higher in acute phlegmonous appendicitis than in gangrenous appendicitis (p = 0.000). IL-5 blood levels were similar in both pathologic and control groups (p > 0.05). In the appendicular lavage fluid, higher levels of IL-5 were observed in the phlegmonous appendicitis group (p = 0.056). We found a positive correlation between the appendicular wall eosinophilic infiltration and the IL-5 concentrations, in both the blood and the appendicular lavage fluid, supporting the IL-5 reliance in eosinophil local infiltration. We observed the highest presence of eosinophils at phlegmonous appendicitis walls. In conclusion, the present data are compatible with a hypersensitivity type I allergic reaction in the target organ, the appendix, during the phlegmonous phase of appendicitis.