Publicação

Quantification of pharmaceutical compounds in wastewater samples by Near Infrared Spectroscopy (NIR)

Ver documento

Detalhes bibliográficos
Resumo:The quantification of pollutants, as pharmaceuticals, in wastewater is an issue of special concern. Usually, typical methods to quantify these products are time and reagent consuming. This paper describes the development and validation of a Fourier transform near-infrared (FT-NIR) spectroscopy methodology for the quantification of pharmaceuticals in wastewaters. For this purpose, 276 samples obtained from an activated sludge wastewater treatment process were analyzed in the range of 200 cm1 to 14000 cm1, and further treated by chemometric techniques to develop and validate the quantification models. The obtained results were found adequate for the prediction of ibuprofen, sulfamethoxazole, 17-estradiol and carbamazepine with coefficients of determination (R2) around 0.95 and residual prediction deviation (RPD) values above four, for the overall (training and validation) data points. These results are very promising and confirm that this technology can be seen as an alternative for the quantification of pharmaceuticals in wastewater.
Autores principais:Quintelas, Cristina
Outros Autores:Mesquita, Daniela P.; Ferreira, Eugénio C.; Amaral, A. Luís
Assunto:NIR spectroscopy pharmaceuticals PCA PLS
Ano:2019
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade do Minho
Idioma:inglês
Origem:RepositóriUM - Universidade do Minho
Descrição
Resumo:The quantification of pollutants, as pharmaceuticals, in wastewater is an issue of special concern. Usually, typical methods to quantify these products are time and reagent consuming. This paper describes the development and validation of a Fourier transform near-infrared (FT-NIR) spectroscopy methodology for the quantification of pharmaceuticals in wastewaters. For this purpose, 276 samples obtained from an activated sludge wastewater treatment process were analyzed in the range of 200 cm1 to 14000 cm1, and further treated by chemometric techniques to develop and validate the quantification models. The obtained results were found adequate for the prediction of ibuprofen, sulfamethoxazole, 17-estradiol and carbamazepine with coefficients of determination (R2) around 0.95 and residual prediction deviation (RPD) values above four, for the overall (training and validation) data points. These results are very promising and confirm that this technology can be seen as an alternative for the quantification of pharmaceuticals in wastewater.