Publicação

Energy performance of a service building: Comparison between EnergyPlus and Revit

Ver documento

Detalhes bibliográficos
Resumo:Currently, the energy consumption study in buildings is very important, since it is one of the sectors of activity where there is great potential to improve energy efficiency. On the market, there are several simulation software, and the aim of this work consists in conducting a comparison between two dynamic simulation software, EnergyPlus, and Revit, with respect to the results obtained of thermal loads and annual energy consumption of a service building. In the simulation using EnergyPlus, an annual energy consumption of 442 MWh was obtained, that compares with 533 MWh when using Revit. Concerning the thermal loads in the sales area of the hypermarket, the simulation results for the thermal loads were the following: 761 kW for heating and 79 kW for cooling, versus 924 kW for heating and 86 kW for cooling when using the EnergyPlus and the Revit software, respectively. This discrepancy between the values obtained could be due to the limited selection of climatic files in Revit as well as the different definitions of the HVAC systems.
Autores principais:Silva, João Pedro Vasconcelos
Outros Autores:Brás, José; Noversa, Ricardo; Rodrigues, Nelson José Oliveira; Martins, Luís Barreiros; Teixeira, J. Carlos; Teixeira, S. F. C. F.
Assunto:Energy performance Services building Simulation Engenharia e Tecnologia::Engenharia Mecânica
Ano:2020
País:Portugal
Tipo de documento:comunicação em conferência
Tipo de acesso:acesso restrito
Instituição associada:Universidade do Minho
Idioma:inglês
Origem:RepositóriUM - Universidade do Minho
Descrição
Resumo:Currently, the energy consumption study in buildings is very important, since it is one of the sectors of activity where there is great potential to improve energy efficiency. On the market, there are several simulation software, and the aim of this work consists in conducting a comparison between two dynamic simulation software, EnergyPlus, and Revit, with respect to the results obtained of thermal loads and annual energy consumption of a service building. In the simulation using EnergyPlus, an annual energy consumption of 442 MWh was obtained, that compares with 533 MWh when using Revit. Concerning the thermal loads in the sales area of the hypermarket, the simulation results for the thermal loads were the following: 761 kW for heating and 79 kW for cooling, versus 924 kW for heating and 86 kW for cooling when using the EnergyPlus and the Revit software, respectively. This discrepancy between the values obtained could be due to the limited selection of climatic files in Revit as well as the different definitions of the HVAC systems.