Publicação

Seismic capacity of unstrengthened and FRP strengthened masonry arches: tilting test and nonlinear numerical analysis

Ver documento

Detalhes bibliográficos
Resumo:Cultural heritage preservation requires a deeper understanding of their seismic response and imposes the use of effective strengthening methods. Fibre-reinforced polymers (FRP) have emerged as an effective solution for strengthening masonry structural elements. The decision over the optimal configuration for a FRP-based strengthening is a trade-off between different objective functions such as strength, inelastic stiffness and cost. Although some studies have explored design alternatives and topology optimisation, experimental investigation remains limited, especially regarding the evaluation of seismic response. This study investigates the seismic capacity of unstrengthened and strengthened mortared–masonry arches through tilting table experiments and numerical simulations. The optimal strengthening arrangement is obtained through topology optimisation, and experimental results demonstrate its performance. A three-dimensional numerical model, following a macro-modelling approach through the so-called concrete damage plasticity material model, is adopted. Numerical results are validated with existing literature and experimental data. A parametric study is conducted for full-scale arches to evaluate the effect of dimensions and the embrace angle of masonry arches. The study reveals that the numerical model successfully replicates masonry arches' nonlinear behaviour and hinge mechanism. In addition, both experimental and numerical results highlight the effectiveness of optimised strengthening placement achieved through topology optimisation.
Autores principais:Tarhan, İsmail Hakkı
Outros Autores:Savalle, Nathanaël; Uysal, Habib; Silva, Luís Carlos Martins; Lourenço, Paulo B.
Assunto:FE-macro-modelling approach Fibre-reinforced polymer Full-scale masonry arches Nonlinear numerical analysis Seismic capacity evaluation Strengthening Tilting table test
Ano:2025
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso restrito
Instituição associada:Universidade do Minho
Idioma:inglês
Origem:RepositóriUM - Universidade do Minho
Descrição
Resumo:Cultural heritage preservation requires a deeper understanding of their seismic response and imposes the use of effective strengthening methods. Fibre-reinforced polymers (FRP) have emerged as an effective solution for strengthening masonry structural elements. The decision over the optimal configuration for a FRP-based strengthening is a trade-off between different objective functions such as strength, inelastic stiffness and cost. Although some studies have explored design alternatives and topology optimisation, experimental investigation remains limited, especially regarding the evaluation of seismic response. This study investigates the seismic capacity of unstrengthened and strengthened mortared–masonry arches through tilting table experiments and numerical simulations. The optimal strengthening arrangement is obtained through topology optimisation, and experimental results demonstrate its performance. A three-dimensional numerical model, following a macro-modelling approach through the so-called concrete damage plasticity material model, is adopted. Numerical results are validated with existing literature and experimental data. A parametric study is conducted for full-scale arches to evaluate the effect of dimensions and the embrace angle of masonry arches. The study reveals that the numerical model successfully replicates masonry arches' nonlinear behaviour and hinge mechanism. In addition, both experimental and numerical results highlight the effectiveness of optimised strengthening placement achieved through topology optimisation.