Manual segmentation of 12 layers of the retina and choroid through SD-OCT in intermediate AMD
| Resumo: | Purpose: To evaluate the repeatability and reproducibility of the segmentation of 12 layers of the retina and the choroid, performed manually by SD-OCT, along the horizontal meridian at three different temporal moments, and to evaluate its concordance with the same measurements performed by two other operators in intermediate AMD. Methods: A cross-sectional study of 40 eyes from 40 subjects with intermediate AMD was conducted. The segmentation was performed manually, using SD-OCT. The 169 measurements per eye were repeated at three time points to study the intra-operator variability. The same process was repeated a single time by two different trained operators for the inter-operator variability. Results: Forty participants (28 women and 12 men) were enrolled in this study, with an average age of 76.4 ± 8.2 (range, 55-92 years). Overall, the maximum values of the various structures were found in the 3 mm of the macula. Intra-operator variability: the highest ICC values turned out to be discovered in thicker locations. Inter-operator variability: except correlation values of 0.826 (0.727; 0.898) obtained in the OPL (T2.5) and 0.634 (0.469; 0.771) obtained in the IPL (N2), all other correlation values were >0.92, in most cases approaching higher values like 0.98. Conclusion: The measurements of several layers of the retina and the choroid achieved at 13 locations presented a good repeatability and reproducibility. Manual quantification is still an alternative for the weaknesses of automatic segmentation. Locations of greatest concordance should be those used for the clinical control and monitoring. |
|---|---|
| Autores principais: | Camacho, Pedro |
| Outros Autores: | Dutra-Medeiros, Marco; Salgueiro, Luís; Sadio, Sílvia; Rosa, Paulo C. |
| Assunto: | Data accuracy Diagnostic imaging Macular degeneration Ophthalmology |
| Ano: | 2021 |
| País: | Portugal |
| Tipo de documento: | artigo |
| Tipo de acesso: | acesso aberto |
| Instituição associada: | Universidade Nova de Lisboa |
| Idioma: | inglês |
| Origem: | Repositório Institucional da UNL |
| Resumo: | Purpose: To evaluate the repeatability and reproducibility of the segmentation of 12 layers of the retina and the choroid, performed manually by SD-OCT, along the horizontal meridian at three different temporal moments, and to evaluate its concordance with the same measurements performed by two other operators in intermediate AMD. Methods: A cross-sectional study of 40 eyes from 40 subjects with intermediate AMD was conducted. The segmentation was performed manually, using SD-OCT. The 169 measurements per eye were repeated at three time points to study the intra-operator variability. The same process was repeated a single time by two different trained operators for the inter-operator variability. Results: Forty participants (28 women and 12 men) were enrolled in this study, with an average age of 76.4 ± 8.2 (range, 55-92 years). Overall, the maximum values of the various structures were found in the 3 mm of the macula. Intra-operator variability: the highest ICC values turned out to be discovered in thicker locations. Inter-operator variability: except correlation values of 0.826 (0.727; 0.898) obtained in the OPL (T2.5) and 0.634 (0.469; 0.771) obtained in the IPL (N2), all other correlation values were >0.92, in most cases approaching higher values like 0.98. Conclusion: The measurements of several layers of the retina and the choroid achieved at 13 locations presented a good repeatability and reproducibility. Manual quantification is still an alternative for the weaknesses of automatic segmentation. Locations of greatest concordance should be those used for the clinical control and monitoring. |
|---|