Manual segmentation of 12 layers of the retina and choroid through SD-OCT in intermediate AMD

Ver documento

Detalhes bibliográficos
Resumo:Purpose: To evaluate the repeatability and reproducibility of the segmentation of 12 layers of the retina and the choroid, performed manually by SD-OCT, along the horizontal meridian at three different temporal moments, and to evaluate its concordance with the same measurements performed by two other operators in intermediate AMD. Methods: A cross-sectional study of 40 eyes from 40 subjects with intermediate AMD was conducted. The segmentation was performed manually, using SD-OCT. The 169 measurements per eye were repeated at three time points to study the intra-operator variability. The same process was repeated a single time by two different trained operators for the inter-operator variability. Results: Forty participants (28 women and 12 men) were enrolled in this study, with an average age of 76.4 ± 8.2 (range, 55-92 years). Overall, the maximum values of the various structures were found in the 3 mm of the macula. Intra-operator variability: the highest ICC values turned out to be discovered in thicker locations. Inter-operator variability: except correlation values of 0.826 (0.727; 0.898) obtained in the OPL (T2.5) and 0.634 (0.469; 0.771) obtained in the IPL (N2), all other correlation values were >0.92, in most cases approaching higher values like 0.98. Conclusion: The measurements of several layers of the retina and the choroid achieved at 13 locations presented a good repeatability and reproducibility. Manual quantification is still an alternative for the weaknesses of automatic segmentation. Locations of greatest concordance should be those used for the clinical control and monitoring.
Autores principais:Camacho, Pedro
Outros Autores:Dutra-Medeiros, Marco; Salgueiro, Luís; Sadio, Sílvia; Rosa, Paulo C.
Assunto:Data accuracy Diagnostic imaging Macular degeneration Ophthalmology
Ano:2021
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Universidade Nova de Lisboa
Idioma:inglês
Origem:Repositório Institucional da UNL
Descrição
Resumo:Purpose: To evaluate the repeatability and reproducibility of the segmentation of 12 layers of the retina and the choroid, performed manually by SD-OCT, along the horizontal meridian at three different temporal moments, and to evaluate its concordance with the same measurements performed by two other operators in intermediate AMD. Methods: A cross-sectional study of 40 eyes from 40 subjects with intermediate AMD was conducted. The segmentation was performed manually, using SD-OCT. The 169 measurements per eye were repeated at three time points to study the intra-operator variability. The same process was repeated a single time by two different trained operators for the inter-operator variability. Results: Forty participants (28 women and 12 men) were enrolled in this study, with an average age of 76.4 ± 8.2 (range, 55-92 years). Overall, the maximum values of the various structures were found in the 3 mm of the macula. Intra-operator variability: the highest ICC values turned out to be discovered in thicker locations. Inter-operator variability: except correlation values of 0.826 (0.727; 0.898) obtained in the OPL (T2.5) and 0.634 (0.469; 0.771) obtained in the IPL (N2), all other correlation values were >0.92, in most cases approaching higher values like 0.98. Conclusion: The measurements of several layers of the retina and the choroid achieved at 13 locations presented a good repeatability and reproducibility. Manual quantification is still an alternative for the weaknesses of automatic segmentation. Locations of greatest concordance should be those used for the clinical control and monitoring.