Publicação

The association of the step duration in an incremental protocol in the rower ergometer and the maximal lactate steady state intensity

Ver documento

Detalhes bibliográficos
Resumo:ABSTRACT This study aims to analyse which are better step duration related to the maximum lactate steady-state test (MLSS) intensity and the intensity equivalent to the accumulation of 4mmol/L lactate (AnT4) determined through an incremental protocol using a rowing ergometer, using different steps durations (step3min, step5min, step7min). Ten elite Portuguese rowers (25.1± 4.82 years; 177.5± 5.50 cm; 69.8± 2.74 kg) performed rowing ergometer protocols to determine the maximum lactate steady state (MLSS). Subsequently, incremental tests were realised to determine AnT4, using different step durations (step3min, step5min, step7min). The results showed a strong correlation between MLSS and AnT4 (r> 0.90; p< 0.001) obtained AnT different steps (step3min, step5min, step7min). However, the determined intensity equivalent to 4 mmol/L obtained with different step durations that showed the highest correlation with MLSS (246.5± 35.20W) was verified in the protocol of 7minute steps (251.5± 35,72W). The present study indicates that the use of 7 minutes steps is the most appropriate for determining the AnT4 intensity related to the aerobic component of a high-performance rowing athlete.
Autores principais:Fraga,Pedro
Outros Autores:Rama,Luis Manuel Pinto Lopes; Santos,José Augusto Rodrigues dos; Oliveira,Eduardo Nuno Moitas de
Assunto:anaerobic threshold maximum lactate steady-state test steptest Concept2 rowing
Ano:2023
País:Portugal
Tipo de documento:artigo
Tipo de acesso:acesso aberto
Instituição associada:Fundação para a Ciência e Tecnologia
Idioma:inglês
Origem:SciELO Portugal
Descrição
Resumo:ABSTRACT This study aims to analyse which are better step duration related to the maximum lactate steady-state test (MLSS) intensity and the intensity equivalent to the accumulation of 4mmol/L lactate (AnT4) determined through an incremental protocol using a rowing ergometer, using different steps durations (step3min, step5min, step7min). Ten elite Portuguese rowers (25.1± 4.82 years; 177.5± 5.50 cm; 69.8± 2.74 kg) performed rowing ergometer protocols to determine the maximum lactate steady state (MLSS). Subsequently, incremental tests were realised to determine AnT4, using different step durations (step3min, step5min, step7min). The results showed a strong correlation between MLSS and AnT4 (r> 0.90; p< 0.001) obtained AnT different steps (step3min, step5min, step7min). However, the determined intensity equivalent to 4 mmol/L obtained with different step durations that showed the highest correlation with MLSS (246.5± 35.20W) was verified in the protocol of 7minute steps (251.5± 35,72W). The present study indicates that the use of 7 minutes steps is the most appropriate for determining the AnT4 intensity related to the aerobic component of a high-performance rowing athlete.