Document details

Evaluation of the binding of four anti-tumor Casiopeinas to human serum albumin

Author(s): Correia, Isabel ; Borovic, Sladjana ; Cavaco, Isabel ; Matos, Cristina P. ; Roy, Somnath ; Santos, Hugo M. ; Fernandes, Luz ; Capelo, Jose L. ; Ruiz-Azuara, Lena ; Pessoa, Joao Costa

Date: 2017

Persistent ID: http://hdl.handle.net/10400.1/12978

Origin: Sapientia - Universidade do Algarve

Subject(s): Copper(Ii) complexes; Dna-binding; Anticancer agents; Heterocyclic bases; Crystal-structures; Cleavage activity; Ligand-binding; Fluorescence; Ternary; 1,10-Phenanthroline; Anti-tumor; Human serum albumin; Binding constants; Circular dichroism


Description

The metal complexes designated by Casiopeinas (R) are mixed-ligand Cu-II-compounds some of them having promising antineoplastic properties. We report studies of binding of Cu(glycinato)(4,7-dimethyl-1,10-phenanthroline) (Cas-II-Gly (1)), Cu(acetylacetonato)(4,7-dimethy1-1,10-phenanthroline) (Cas-III-Ea (2)), Cu(glycinato) (4,4'-dimethyl-2,2'-bipyridine) (Cas-W-Gly (3)) and Cu(acetylacetonato)(4,4'-dimethyl-2,2'-bipyridine) (Cas-IIIia (4)) to human serum albumin (HSA) by circular dichroism (CD), Electron paramagnetic resonance (EPR) and fluorescence spectroscopy. The results indicate that HSA may bind up to three molecules of the tested Casiopeinas. This is confirmed by inductively coupled plasma atomic absorption spectroscopy measurements of samples of HSA-Casiopeinas after passing by adequate size-exclusion columns. The binding of Cas-II-Gly to HSA was also confirmed by MALDI-TOF mass spectrometric experiments. In the physiological range of concentrations the Casiopeinas form 1:1 adducts with HSA, with conditional binding constants of ca. 1 x 10(9) (1), 4 x 10(7) (2), 1 x 10(6) (3) and 2 x 10(5) (4), values determined from the CD spectra measured, and the fluorescence emission spectra indicates that the binding takes place close to the Trp214 residue. Overall, the data confirm that these Casiopeinas may bind to HSA and may be transported in blood serum by this protein; this might allow some selective tumor targeting, particularly in the case of Cas-Il-Gly. In this work we also discuss aspects associated to the reliability of the frequently used methodologies to determine binding constants based on the measurement of fluorescence emission spectra of solutions containing low concentrations of proteins such as HSA and BSA, by titration with solutions of metal complexes.

Document Type Journal article
Language English
Contributor(s) Sapientia
facebook logo  linkedin logo  twitter logo 
mendeley logo

Related documents

No related documents